SPECIFICATIONS 

 

Model 

X704 

Accuracy  

III 

Sensitivity 

1.5~3.0mV/V  

Linear 

0.01%        

0.01%F.S 

Voltage 

DC: 5V 

Division  

1/2/5 option 

Speed 

20 times per second  

Internal resolution 

300,00/600,00 

 

 

POWER SOURCE 

 

Input:  

AC 120~240V 

Output 

DC 10V/600mA 

 

 

POWER CONSUMPTION   

 

1. Main system: 

 

Approx. 24.1mA 

2. Main system (RS-232):  Approx. 44mA 

3. Standby:   

 

Approx. 19.2mA 

4. Battery duration:  

Approx. 120 

 

COMPONENTS INCLUDED  

 

1. This user manual (please read it carefully before to use the indicador).  

2. The indicator Series X704  

3. The AC/Adaptor . 

 

!

Keep the original package. It could be useful in the future to transport the indicator.

 

 

 

 

 

 

 

Содержание X704

Страница 1: ...X704 WEIGHT NDI I CATOR...

Страница 2: ...5 I9 57 F5A...

Страница 3: ...maged Disposal In conformance with the European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE this device may not be disposed of in domestic waste This also applies to countri...

Страница 4: ...d 4 Connection of indicator X704 to a loadcell 5 Requirements for an optimum installation 5 Installation 6 Keyboard description 6 Piece counting function 7 Tare function 7 Weights accumulation 7 Funct...

Страница 5: ...Input AC 120 240V Output DC 10V 600mA POWER CONSUMPTION 1 Main system Approx 24 1mA 2 Main system RS 232 Approx 44mA 3 Standby Approx 19 2mA 4 Battery duration Approx 120 COMPONENTS INCLUDED 1 This u...

Страница 6: ...r according to the following requirements a Don t expose the indicator to direct sunlight b Don t submit it to atmospheres with corrosive gases c Keep it in an environment free of dust and dirt c Work...

Страница 7: ...nction 1 Press this key to turn on the indicator Function 2 To reset the weight to 0 The displayed weight value has to be less than 2 of maximum capacity Function 3 To subtract the weight of a contain...

Страница 8: ...e weighed in the container 5 Display will show the product s weight net weight Note The container s weight must be higher than 2 of maximum capacity WEIGHTS ACCUMULATION 1 Place the product on the pla...

Страница 9: ...00 Press to change the parameter Press to select the desired mode AOFF00 Auto power off disable AOFF01 The indicator will auto power off in 1 minute if not use it Press to exit UF 4 Standby setting Pr...

Страница 10: ...l show ECF __1 2 Press to select the desired parameter from ECF 1 to ECF 3 Parameter Function Operation ECF 1 Check maximal load span Press display will show CALZ empty the platform and press again th...