background image

 

 

 

N: 2.91kg 

 

C: 54pcs 

Accumulation mode 

NO: 0002 

 

S: 5.82kg 

Accumulation with counting mode: 

NO: 0002 

 

 

C: 108pcs 

 

 

S: 5.82kg 

§15. Safety precautions 

1.

 

Do not expose indicators to either direct sun light or any heat sources. 

2.

 

Do not use indicators in hazardous area or in dusty environments. 

3.

 

Weight cannot more than max weighing 

4.

 

Do not use strong solvents (such as: benzene, nitric acid oil) to clean the indicators. 

5.

 

Never flood the Indicator, immerse it in liquid or pour liquids on it. 

6.

 

Do not open the indicator! The warranty is void if this stipulation is ignored. The indicator may only be 

opened by authorized persons. 
7.

 

Battery is recharged when AC power connects.   

8.

 

Use short pin to test indicator: if indicator doesn’t displays weight number, please switch off it, take off 

load  cell  connector  and  take  on  short  pin.  Switch  on  indicator,  after  displays  0-9  self-test  patterns.  See 
following two situations: 
a. Indicator displaying one number means indicator works well.   
b. Indicator displaying many mass numbers means indicator needs repair. 

§16. Services 

The Warranty time is in one year after sale date of non-human failure. Indicator is lifelong service.

 

(NOTE: Battery is not under warranty)

 

§17. LED Error Code 

Code 

Meaning 

 

OUEr

 

 

Weight > FS + 9d

 

–OUEr 

 

Weight 

  -20d or 100%FS (in double-way weighing mode) 

 

30% battery warning to recharge the battery 

Weight number flashing 

10% battery warning to recharge the battery 

bxxxxx

 

Wireless weighing transmitter 10% battery warning to recharge the battery 

 
 
 
 
 
 
 
 
 

Содержание X1FM

Страница 1: ...9 9...

Страница 2: ...5 I9 57 F5A...

Страница 3: ...ame Wireless communication frequencies are set in factory and user cannot change Regular wireless communication frequency is 430MHz If user wants to use two or more than two set of wireless weighing i...

Страница 4: ...ss Press CAL SP SEt Indicator in calibration mode Indicator in configuration mode Press d 1 Select division 3 Press Or 0 d 2 0 001 0 002 0 005 10 20 50 100 200 500 0 10 0 20 0 50 1 2 5 0 1 0 2 0 5 0 0...

Страница 5: ...lt baud rate 2400 9 Press 0 Confirm configuration 5 Wireless Communicate After above configuration set the wireless communicate Step Operation Displaying Descriptions 1 Press Press Press Press Press C...

Страница 6: ...tor in calibration mode 2 Press SEt Indicator in configuration mode 3 Press A d ADC counts display 4 Press 43125 Enter to check ADC counts and display 43125 5 Press 0 Return to weighing mode 8 Factory...

Страница 7: ...es e g n 12 Note one weighing result only can accumulate one time next accumulation weight must after weight 20d 4 High resolution In weighing mode press to display the weight in X10 resolution and la...

Страница 8: ...itch on indicator and display Pbt 85 means battery capacity is 85 10 Remind charge battery When battery capacity is 30 turns on to remind user charge battery When battery capacity is 10 display flashe...

Страница 9: ...eighing mode 9 Press n 8 Display number of samples 10 Press 0 C 47 Delete accumulation weight and return to counting mode When indicator displays accumulation times press 0 to delete accumulation weig...

Страница 10: ...en AC power connects 8 Use short pin to test indicator if indicator doesn t displays weight number please switch off it take off load cell connector and take on short pin Switch on indicator after dis...

Страница 11: ...5 I9 57 F5A...

Страница 12: ...G9F 5BI5 9 9...

Отзывы: