■ Float
- Make sure that float holder which is connected with the measuring tape is facing upward, when
installing the float.
- The position of the float should be located away from the inlet of the fluid entering the tank to prevent
the float from being affected by the fluid flow or swirling. If the float is inevitably to be installed at the
inlet of the fluid, the guide pipe should be installed to protect the float. [Refer to Figure.11]
■ Top Anchor, Guide Wire
- Hang the anchor on the guide wire and set the location of the bottom anchor. Ensure that the
top anchor and flange are positioned vertically to each other. [Refer to Figure.12]
- Since the distance between the bottom anchor and guide wire is 440mm, the distance from
the center line of the top anchor should be set to 440mm.
[Figure. 12] Top Anchor Installation Cautions
[Figure. 11] Float Installation Site