Specifications
Product
Model
HCC-96RF-C
HCC-96RF-CH
HCC-96RF-S
Probe Type
Main Probe
Main +
Compensation Probe
Mounting
Flange or Screw
Ambient temperature
-20˚C ~ +60˚C
Process temperature
Max. 80˚C
Max. 150˚C
Max. 240˚C
Process Pressure
Up to 20kg/cm
2
Up to 10kg/cm
2
Power Source
AC 90~240V, 50Hz/60Hz (Std.) / DC +24V (Opt.)
Output Signal
DPDT
Contact Rating
AC 250V, 5A / DC 30V, 5A
Enclosure
Weather-Proof
Wetted Parts Material
SUS 316L + Teflon
SUS 316L + PPS
Process Connection
PT 1” Screw
50A JIS 10K RF
Housing ; Cable Entry
PBT ; 2-PF 1/2” (F),
IP65 (Std.)
AL. ; 2-PF 1/2” (F),
IP66 (Opt.)
AL. ; 2-PF 1/2” (F),
IP66
AL. ; 2-PF 1/2” (F),
IP66
Amplifier Specification
Module
M-96RFC
M-96RFS
Microprocessor
16 Bit Microprocessor
Oscillation Frequency
420KHz @ ±10KHz
154KHz @ ±10KHz
Dielectric Constant
1.5 @ Min.
Sensitivity
(Adjustment)
1pF ~ 80pF
1pF ~ 20pF
Function
(Adjustment)
■
Measurement Range
■
Relay Delay Time
■
Relay Return Time
■
Relay Out Control (Normal/Reverse)
Relay Delay Time
(Adjustment)
0.5Sec. @ Min. / 1 ~ 10Sec. @ 0.1Sec. Resolution
Relay Return Time
(Adjustment)
0.5Sec. @ Min. / 1 ~ 10Sec. @ 0.1Sec. Resolution
Relay Contact Out Control Normal Close @ Default.
Status Indicator
Bi-Color LED [Green / Red / Orange]
Detection Indicator
Red LED
Relay Control Indicator
Green LED
UART
Monitoring
Ambient Temperature
-20˚C ~ +80˚C