3.
M-96RFS UART Monitoring
■ Monitoring Method
□ You can only check the state of the adjusted setting values using PC or Smartphone.
□ The execution method is the same using PC or Smartphone. (Password: 1975)
□ Run Screen Component: You can check the sensor measurement status, sensitivity
setting value, relay setting, etc.
■ Monitoring Method Using PC
□ Component: PC, USB Cable(typical USB to Micro USB B), UART Adaptor..
[USB Cable]
[M-96RFS PC UART Component]
[M-96RFS PC UART Run Screen]
[M-96RFS PC UART Run Screen Component Function]
Relay Contact Status
Sensitivity Threshold Voltage
Current Measurement Voltage
Relay Delay Time Setup Time State
Relay Return Time Setup Time State
Board Temperature