3.
Configuration of Setting Menu
No.
Contents
Description
[02]
Low Value Set
Set the Low value by viewing the current Capacitance value
[03]
High Value Set
Set the High value by viewing the current Capacitance value
[08]
Relay Contact Type
N.O or N.C (Default : N.O)
[09]
Relay Delay Time Set
0.5 ~ 10 sec. (Default 0.5 sec @ 0.5 sec Step ADJ.)
[11]
LOW Capacity fine Adjustment
Find adjustment from settled capacitance value.
(0.1%, 1%, 10%)
[12]
HIGH Capacity fine Adjustment
[30]
Rotation Time Set
0.5 ~ 10 sec. (Default 3 sec @ 0.5 sec Step ADJ.)
[31]
'C' Display On/Off
Rotation ‘C’ select display
(Current Capacitance value)
[32]
'H' Display On/Off
Rotation ‘H’ select display
(High Capacitance setting value)
[33]
'L' Display On/Off
Rotation ‘L’ select display
(Low Capacitance setting value)
[34]
'A↔B’ Display On/Off
Rotation ‘A↔B’ select display
(Relay Contact Type & ON/OFF)
[90]
Error Number Output
Display of error number according to malfunction
[91]
Capacity value Output
Low, High, display current Capacitance value
[100]
Reset
Reset the all setting