HCC-95P Series
HITROL CO.,LTD.
8
Precautions
for Attachment
Wiring
■ Connect correctly AC(90~240V) or DC(+24V) power to the power specification.
■ Make sure to connect the DC power with correct po, -).
■ Do not connect the wire with the power connected.
■ It provides DPDT output by default, wired COM and N.O terminals when using the
high alarm.
■ External grounding shall be completed.
In case of Ex-proof products, apply the power after tightening the cover after wiring.
■ When installing the sensor, avoid shaking or obstacle.
■ Do not install in openings that are prone to severe fluid flow, mechanical damage, or
chattering.
■ Check the specification of temperature and pressure generated inside the tank.
■ Condensation may occur if the temperature of the housing differs significantly from the
ambient temperature, so dehumidifier shall be filled or ventilated(gortex) before use.
■ Connect the flanges or bolts with the same specifications.
■ Make sure to insert gaskets between flanges. (Select the gaskets in consideration of
the temperature of the content and the pressure inside the container.)
For Ex-proof products, it shall be installed with an appropriate grade for environment.