◆ Smart tariff (Default for input 5)
This function can be used to block or limit the heat pump. It allows an external Smart switch
device to switch off or limit the heat pump during a period of peak electricity demand. Terminals
16 and 19 of the TB2.
T
T
Common
Line
Smart F.
Input 5
16
19
◆
DHW boost (Default for input 6)
This function allows a request for a one-time heating up of the domestic hot water temperature.
The input can be sent by a push button, a NC contact and a NO contact. This input is switched on
terminals 16 and 20 of the TB2.
Common
Line
DHW Boost
input 6
16
20
◆
Power Meter (Default for input 7)
This function is used to monitor real consumption of the system by means an external power
meter device connected at this input. The calculation method is done by measuring real
consumption of the whole installation with one power meter device or 2 separate power meter
(one for indoor unit and another one for outdoor unit.
Common
Line
Power M.
input 7
16
21