28
PMML0600 rev.0 - 06/2022
3
CONSIDERA
TIONS
ELEC
TRICAL D
AT
A
3.1.1 Monobloc system
◆
YUTAKI M (R32)
RASM-(2-3)VRE
Model
Power
supply
Applicable voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-2VRE
~ 230V
50Hz
253
207
Without DHW tank heater
4.8
1.00
5.5
1.14 10.6 2.32
With DHW tank heater
4.8
1.00
18.8 3.89 23.1 5.07
RASM-3VRE
Without DHW tank heater
9.4
1.94
8.9
1.84 16.0 3.54
With DHW tank heater
9.4
1.94
22.2 4.59 28.5 6.29
NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot
water tank accessory “DHWT‑(200/300)S‑3.0H2E”.
RASM-(4-7)(V)R1E
Model
Power
supply
Applicable
voltage
Operation mode
Cooling
operation
Heating
operation
MC
(A)
Max.
IPT
(kW)
U
max.
(V)
U min.
(V)
RNC
(A)
IPT
(KW)
RNC
(A)
IPT
(KW)
RASM-4VR1E
~ 230V
50Hz
253
207
Without DHW tank heater
14.3
3.26
10.4
2.36
28.8
5.98
With DHW tank heater
10.2
2.18
20.6
4.40
41.3
8.81
RASM-5VR1E
Without DHW tank heater
16.0
3.65
11.7
2.67
28.8
5.98
With DHW tank heater
10.2
2.18
20.6
4.40
41.3
8.81
RASM-6VR1E
Without DHW tank heater
17.7
4.04
12.7
2.89
28.8
5.98
With DHW tank heater
10.2
2.18
20.6
4.40
41.3
8.81
RASM-4R1E
3N~ 400V
50Hz
440
360
Without DHW tank heater
5.2
3.26
3.8
2.36
16.3
9.17
With DHW tank heater
5.2
2.19
11.9
4.95
28.8
12.01
RASM-5R1E
Without DHW tank heater
5.8
3.65
4.3
2.67
16.3
9.17
With DHW tank heater
5.2
2.18
11.9
4.95
28.8
12.01
RASM-6R1E
Without DHW tank heater
6.5
4.04
4.6
2.89
16.3
9.17
With DHW tank heater
5.2
2.18
11.9
4.95
28.8
12.01
RASM-7R1E
Without DHW tank heater
7.2
4.46
5.8
3.62
16.3
9.17
With DHW tank heater
5.2
2.18
11.9
4.95
28.8
12.01
NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot
water tank accessory “DHWT‑(200/300)S‑3.0H2E”.