Workflow for creating and managing Thin Image pairs
on page 128
•
Storing snapshot data or cloning pairs
Host server stoppages and device recognition issues
If you boot or reboot host servers, such as HP-UX or Solaris, or if you use the
host server to run the read command on a V-VOL to recognize a device, keep
the following items in mind.
• You cannot change the volume of the device recognized by the host server
to a V-VOL.
• Before booting or rebooting the host server or running the command for
recognizing devices, complete the following:
1.
Create the Thin Image pair.
2.
Store the snapshot data (or clone pairs).
3.
Ensure the V-VOL pair recognized by the host server is in "PSUS"
status or an unpaired volume.
If you do not fulfill all of the conditions listed above, the devices may not be
recognized, or failures can occur and the host server can stop.
If you booted or rebooted host servers, or if you used the host server to run
the commands to recognize devices and the host server was stopped, use the
following workflow to run the commands:
1.
Forcibly stop the process of the command and those of its parent
process.
2.
Create the Thin Image pair.
3.
Store the snapshot data (or clone pairs).
4.
Rerun the command to recognize devices.
On the server (including CCI), the emulation type of the V-VOL is shown with
a zero (0), such as OPEN-0V. If you create a Thin Image pair, specify a
volume whose emulation type is shown with a zero (0) for the S-VOL, such as
OPEN-0V.
Overview of using CCI to run commands through in-band
connections
Use CCI to run commands through an in-band connection to perform Thin
Image tasks. To run the command through an in-band connection, reserve a
volume for use as a command device.
If you use CCI to run commands through an out-of-band connection, you do
not need to reserve a volume.
Caution:
For maximum host I/O performance, use CCI to run commands
through an in-band connection.
120
Configuring Thin Image
Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series
Содержание VSP F1500
Страница 124: ...124 Configuring Thin Image Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 202: ...202 Troubleshooting Thin Image Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 203: ...Troubleshooting Thin Image 203 Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 205: ...Troubleshooting Thin Image 205 Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 320: ...320 Glossary Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 324: ...324 Index Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...
Страница 325: ...Hitachi Thin Image User Guide for Hitachi Virtual Storage Platform G Series and F Series ...