3 - 5
Referrence
Misoperation message
MS-DOS screen-2
SMAP input screen
Model select screen
Screen for verifying model name
Main menu
4.
Starting Adjustment Program (SMAP)
C>A:
A>
C>A:
A>SMAP_IBM 1
***********************************************************
MODEL SELECT
***********************************************************
[1]
××××××××
[2]
××××××××
[3]
××××××××
[4]
××××××××
[5]
××××××××
[P]
NEXT SELECTION
[ESC] END
Please select the type of the set
Press [1] - [5] or [P] or [ESC]
Selected model is ××××××××
Are you sure ? (Y/N)
CAN NOT FIND THE DATA FILE
**** PRESS ANY KEY ****
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
ELECTRIC VOLUME
[C]
ADJUSTMENT
[D]
AUTO FOCUS
[E]
SPOT NOISE
[ESC] END
Please select [A] - [F] or [ESC]
Note: If error message appears during adjustment, refer to "10. Error Messages".
1) Connect the video camera, DSP-R jig and PC as shown in Fig. 2-1, and supply
power to them. (*1)
2) Operate the PC to start MS-DOS . (*2)
3) Make sure that the adjustment floppy disk is write-protected.
4) Insert the adjustment floppy disk into the floppy disk drive of PC.
5) Use the PC keyboard to type A: and press Enter key. (*3) (See the MS-DOS
screen-1 and 2)
6) Type SMAP_IBM (space) 1 and press Enter key. (*4) (See the SMAP input
screen)
7) The SMAP will start: Make sure that the model select screen appears on the
PC display. (*5) (See the model select screen)
8) If the appropriate model is displayed on the model select screen, input the
number to PC. If the appropriate model name is not shown on the model select
screen, input P to PC until the model name appears. (*6)
9) The screen for verifying the model name will appear on PC display: If it is
correct, input Y to PC. If it is incorrect, input N and start over (from step 8).
10) Make sure that the main menu appears on PC display: If it does not appear,
check whether model selection (in step 8) is correct.
*1: If the connection of jig, etc. is inappropriate or power is not supplied, the
adjustment program will not start normally.
*2: For details on how to start MS-DOS, refer to the instruction manual of PC,
since this varies for each PC.
*3: The letter to be input is to designate the drive into which the adjustment
floppy disk has been inserted. If using a drive other than A, designate the
drive.
*4: The number to be input after a space is to designate the serial port no. of
PC. If the PC has two or more serial ports, and the DSP-R jig is connected
to a port other than serial port 1, input the serial port number.
*5: If the model select screen does not appear, make sure of the following:
Power is supplied to the video camera and DSP-R jig.
The designation of drive (in step 5) is correct.
The designation of serial port is correct.
The correct adjustment floppy disk has been correctly inserted.
*6: If an erroneous model name or number is selected, misoperation message
will appear on PC display: Press any key to restore the model select
screen.
To terminate the adjustment program (SMAP):
Press the Esc key once to three times until the PC display returns from
each menu screen to the MS-DOS screen.
When the MS-DOS screen appears on PC display, turn off the video camera
and jig.
C>
MS-DOS screen-1
Press Enter key.
Type SMAP_IBM 1.
Model select (Input the number).
Input Y.
R