– 61 –
AUTO FRESH DEFROSTING
AUTO OPERATION
NICE TEMPERATURE RESERVATION
INFRARED REMOTE CONTROL
After the ON/OFF button is pressed
to stop heating, the outdoor unit is
still working with the OPERATION
lamp lighting.
Fan speed does not change when
fan speed selector is changed
during auto operation.
When on-timer has been
programmed, operation starts before
the preset time has been reached.
Does Nice temperature reservation
function operate during dehumidifying?
Even if the same time is preset,
the operation start time varies.
Timer cannot be set.
The current time display
disappears soon.
The timer has been programmed,
but the preset time disappears.
Auto Fresh Defrosting is carried out : the
system checks the outdoor heat exchanger
and defrosts it as necessary before stopping
operation.
At this point fan speed is automatic.
This is because Nice temperature reservation
function is operating. This function starts
operation earlier so the preset temperature is
reached at the preset time. Operation may start
maximum 60 minutes before the preset time.
It does not work. It works only during cooling
and heating.
This is because Nice temperature reservation
function is operating. The start time varies
according to the load of room. Since load varies
greatly during heating, the operation start time is
corrected, so it will vary each day.
Has the clock been set? Timer cannot be set
unless the clock has been set.
The current time disappears
in approx. 10 seconds. The
time set display has priority.
approx. 3 minutes.
Is the current time past the preset time?
When the preset time reaches the current
time, it disappears.
When the current time is
set the display flashes for
Q8
A8
Q9
A9
Q10
A10
Q11
A11
A12
Q13
A13
Q14
A14
Q15
A15
Q12
Содержание Summit RAC-18YH6
Страница 17: ... 15 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAS 18FH6 RAS 25FH6 INDOOR UNIT ...
Страница 18: ... 16 CONSTRUCTION AND DIMENSIONAL DIAGRAM MODEL RAC 18YH6 RAC 25YH6 OUTDOOR UNIT ...
Страница 22: ... 20 CIRCUIT DIAGRAM MODEL RAS 18FH6 RAS 25FH6 RAS_AW_020 021_A2 2008 02 18 10 17 20 ...
Страница 23: ... 21 RAC 18YH6 RAC 25YH6 MODEL RAS_AW_020 021_A2 11 17 06 11 18 AM 21 ...
Страница 24: ... 22 RAS_AW_022_A3e 2008 02 19 16 33 22 ...
Страница 25: ... 23 Silent RAS_AW_023_A3e 2008 03 06 20 58 23 ...
Страница 27: ... 25 ...
Страница 28: ... 26 ...
Страница 30: ... 28 ...
Страница 31: ... 29 ...
Страница 47: ... 45 ...
Страница 48: ... 46 ...
Страница 50: ... 48 ...
Страница 51: ... 49 ...
Страница 52: ... 50 ...
Страница 54: ... 52 ...
Страница 71: ... 69 SELF DIAGNOSIS LIGHTING MODE MODEL RAC 18YH6 RAC 25YH6 SELF DIAGNOSIS LIGHTING MODE MODEL RAC E10H2 ...
Страница 77: ... 75 ...
Страница 81: ... 79 ...
Страница 82: ... 80 ...
Страница 83: ... 81 ...
Страница 92: ... 90 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 18FH6 RAS 25FH6 ...
Страница 96: ...HITACHI AW NO 0024E RAS 18FH6 RAC 18YH6 RAS 25FH6 RAC 25YH6 ...