9-7
●
On-screen message descriptions
9.2.2 Warning messages
No.
Message
Meaning of message
Remedy
65
Excitation V-ref.
Review
The difference between the ambient
temperature and the standard ambient
temperature exceeded a fixed value.
●
Perform nozzle test and
update the excitation V-ref.
setting.
( Technical manual 6.10)
66
Viscosity Reading
Instability
Measurement results of viscometer vary.
●
Contact your nearest local
distributor.
67
Viscosity
Readings Out of
Range
Viscometer does not function normally.
●
Contact your nearest local
distributor.
68 High Ink Viscosity Ink viscosity is high.
●
Ink viscosity is now adjusted
to normal level.
If print quality is still poor,
replace ink with a new one.
( Technical manual 6.3)
69 Low Ink Viscosity Ink viscosity is low.
.
●
Ink viscosity is now adjusted
to normal level.
If print quality is still poor,
replace ink with a new one.
( Technical manual 6.3)
71 Battery Low M
The engine section built-in battery voltage
is too low.
●
Contact your nearest local
distributor.
●
When making prints, set the
correct calendar time again
from the date/time setup
screen ( 6.2).
72
Calendar Content
Inaccurate
Calendar print contents are not accurate
due to faulty built-in battery.
●
Contact your nearest local
distributor.
75
External
Communication
Error nnn
The external communication function is not
normally exercised.
●
Note the error code and see
that no more errors occur.
81 Ink Low Warning
The ink level in the ink reservoir is too low.
●
Add ink within 60 minutes
( 8.1).
82
Makeup Low
Warning
The makeup level in the makeup reservoir
is too low.
●
Add the makeup within 60
minutes.
( 8.2).
83
Ink Shelf Life
Exceeded
The cumulative ink ejection time exceeded
the preselected alarm time.
●
Replace the ink
( Technical manual 6.3).
84
Ambient
Temperature Too
High
The ambient temperature is higher than the
upper-limit operating temperature.
●
Ensure that the ambient
temperature is within the
operating temperature limits.
85
Ambient
Temperature Too
Low
The ambient temperature is lower than the
lower-limit operating temperature.
●
Ensure that the ambient tem-
perature is within the operat-
ing temperature limits.
Содержание RX