– 39 –
INFO FUNCTION
●
By pressing
(INFO) button, temperature around remote controller and monthly power consumption will be
displayed on the remote controller.
●
After changing the batteries, direct the remote controller towards the indoor unit and press
(INFO) button.
Current calendar and clock will be transmitted from indoor unit.
●
In order to receive information from indoor unit, the distance between remote controller and receiver of indoor units is
within 2 meters.
■
To check temperature around remote controller
■
Current calendar and clock can be retrieved from indoor
unit
■
To check monthly power consumption
Press
(INFO) button.
Temperature will be displayed for 10 seconds.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in
front of indoor unit) and press
(INFO) button. Wait for 2 seconds for signal
transmission.
Once received the current calendar and clock, check whether they are correct or not
by pressing
(CLOCK) button.
●
If there is no power supply to indoor unit or calendar and clock have not been set,
INFO function cannot be used for sending or receiving information.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in
front of indoor unit) and press
(INFO) button. Wait for 2 seconds for signal
transmission.
While temperature around remote controller is displayed, press
(INFO)
button repeatedly. The display will show as below:
this month power consumption amount for heating
last month power consumption
amount for heating
this month power consumption amount for cooling
last
month power consumption amount for cooling
temperature around remote
controller
this month power consumption amount for heating ...... cyclically.
●
If indication is not given, bring remote controller closer to the receiver of the
indoor unit.
●
Indicated value shall be regarded as a guide only.
1
NOTE
●
In case failure occurs to the air conditioner, by pressing
(INFO) button, an error code will be displayed.
Direct the remote controller towards the receiver of indoor unit (within 2 meters in front of indoor unit) and press
(INFO) button. Wait for 2 seconds for signal transmission.
An error code will be displayed.
Call service center and inform the error code.
●
Information of “Monthly power consumption” are not available for model RAM-130NP6A.
●
Info Function to check monthly power consumption.
During installation, in case of power failure or breaker ON / OFF, ensure to set the clock and calendar for each
indoor unit (unit in standby mode or auto restart), for single or multi connection, by pressing
(START / STOP)
button.
Failure to do the above, monthly power consumption amount will not be displayed on the remote controller.
Содержание RAM-36NP2A
Страница 45: ... 43 MODEL RAI 25RPA RAI 35RPA RAI 50RPA WIRING DIAGRAM INDOOR UNIT ...
Страница 46: ...Remote Control CIRCUIT DIAGRAM 45 ...
Страница 47: ...CIRCUIT DIAGRAM MODEL RAI 25RPA RAI 35RPA RAI 50RPA 47 ...
Страница 48: ... 49 ...
Страница 49: ... 51 ...
Страница 52: ... 57 ...
Страница 54: ... 61 ...
Страница 56: ... 65 ...
Страница 57: ... 67 ...
Страница 62: ... 73 ...
Страница 69: ... 80 ...
Страница 70: ... 81 ...
Страница 72: ... 83 1 Power does not come on no operation CHECKING INDOOR UNIT ELECTRICAL PARTS ...
Страница 74: ... 85 ...
Страница 75: ... 86 ...
Страница 76: ... 87 HOW TO CHANGE THE SHIFT VALUE for SETTING TEMPERATURE USING WIRED REMOTE CONTROLLER ...
Страница 77: ... 88 ...
Страница 78: ... 89 ...
Страница 79: ... 90 ...
Страница 80: ... 91 CHECKING THE REMOTE CONTROLLER ...
Страница 81: ... 92 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAI 25RPA RAI 35RPA RAI 50RPA ...
Страница 85: ... 96 MODEL RAI ECPP PANEL ...
Страница 87: ...HITACHI PM NO 0530E Printed in Malaysia RAI 25RPA RAI 35RPA RAI 50RPA ...