background image

–  2  –

SAFETY  PRECAUTION

 

O

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

 

O

Pay  special  attention  to  signs  of  “

!

Warning

”  and  “

!

Caution

”.  The  “Warning”  section  contains  matters  which,  if  not 

observed  strictly,  may  cause  death  or  serious  injury.  The  “Caution”  section  contains  matters  which  may  result  in  serious 
consequences if not observed properly. Please observe all instructions strictly to ensure safety.

 

O

The sign indicate the following meanings.

 

O

Please keep this manual after reading.

PRECAUTIONS  DURING  OPERATION

 

O

Avoid an extended period of direct air 

ß

 ow for your health.

W

A
R
N

I

N
G

!

 

O

Do not insert a 

Þ

 nger, a rod or other objects into the air outlet or inlet. As the fan is rotating 

at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn 
the breaker OFF.

 

O

Do not use any conductor as fuse wire, this could cause fatal accident.

PRECAUTIONS  DURING  SHIFTING  OR  MAINTENANCE

O

  Should abnormal situation arises (like burning smell), please stop operating the unit and turn 

off the circuit breaker. Contact your agent. Fault, short circuit or 

Þ

 re may occur if you continue 

to operate the unit under abnormal situation.

O

Please contact your agent for maintenance. Improper self maintenance may cause electric 
shock and 

Þ

 re.

O

Please contact your agent if you need to remove and reinstall the unit. Electric shock or 

Þ

 re 

may occur if you remove and reinstall the unit yourself improperly.

O

If  the  supply  cord  is  damaged,  it  must  be  replaced  by  the  special  cord  obtainable  at  
authorized service/parts centers.

W

A
R
N

I

N
G

!

O

   

During  thunder  storm,  disconnect  and  turn  off  the  circuit  breaker.

WARNING

PRECAUTIONS  DURING  INSTALLATION

O

  Do  not  reconstruct  the  unit.

 

Water leakage, fault, short circuit or 

Þ

 re may occur if you reconstruct the unit by yourself.

O

  Please ask your sales agent or quali

Þ

 ed technician for the installation of your unit. Water 

leakage,  short  circuit  or 

Þ

 re  may  occur  if  you  install  the  unit  by  yourself.

O

  Please  use  earth  line.

 

Do  not  place  the  earth  line  near  water  or  gas  pipes,  lightning-conductor,  or  the  earth 
line  of  telephone.  Improper  installation  of  earth  line  may  cause  electric  shock.

O

  Be sure to use the speci

Þ

 ed piping set for R410A. Otherwise, this may result in broken 

copper  pipes  or  faults.

O

  A circuit breaker should be installed depending on the mounting site of the unit. Without 

a  circuit  breaker,  the  danger  of  electric  shock  exists.

O

  Do  not  install  near  location  where  there  is 

ß

 ammable  gas.  The  outdoor  unit  may  catch 

Þ

 re  if 

ß

 ammable  gas  leaks  around  it.

O

  Please  ensure  smooth 

ß

 ow  of  water  when  installing  the  drain  hose.

O

  Do  not  install  the  indoor  unit  in  a  machine  shop  or  kitchen  where  vapor  from  oil  or  its 

mist 

ß

 ows to the indoor unit. The oil will deposit on the heat exchanger, thereby reducing 

the  indoor  unit  performance  and  may  deform  and  in  the  worst  case,  break  the  plastic 
parts  of  the  indoor  unit.

CAUTION

!

!

O

 

Spray  cans  and  other  combustibles  should  not  be  located  within  a  meter  of  the  air  outlets 
of  both  indoor  and  outdoor  units.

  As  a  spray  can’s  internal  pressure  can  be  increased  by  hot  air,  a  rupture  may  result.

Make sure to connect earth line.

The sign in the 

Þ

 gure indicates prohibition.

Indicates the instructions that must be followed.

Содержание RAK-18QXA

Страница 1: ... 1 RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA SPLIT TYPE AIR CONDITIONER INDOOR UNIT INDOOR UNIT RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA MODEL ...

Страница 2: ...l cord obtainable at authorized service parts centers W A R N I N G O During thunder storm disconnect and turn off the circuit breaker WARNING PRECAUTIONS DURING INSTALLATION O Do not reconstruct the unit Water leakage fault short circuit or Þre may occur if you reconstruct the unit by yourself O Please ask your sales agent or qualiÞed technician for the installation of your unit Water leakage sho...

Страница 3: ...ater will condense on the air deßector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time O If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved O This appliance is not inten...

Страница 4: ... DEPTH mm 198 MODEL NAME AND DIMENSIONS O Air purifying and deodorizing Þlters are not washable and reusable up to 20 times by using vacuum cleaner or water rinse under running tap water Type number for this air cleansing Þlter is SPX CFH22 Please use this number for ordering when you want to renew it O Air purifying Þlter should be cleaned every month or sooner if noticeable loading occurs When u...

Страница 5: ...ON INDICATOR TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work O By pressing the temporary switch the operation is done in previously set operation mode O When the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode TEMPOR ARY SWITCH TEMPORARY SWITCH Front panel Moveabl...

Страница 6: ...ere is a possibility panel coming off and falling down O Do not apply extra force on the front panel when it is opened up in the upright position Also frequent removal of the front panel from the front cover may cause damage CAUTION O Initially press the left and the right sides of the front panel and Þnally press the central portion until you hear a clicking sound Note O The recommended temperatu...

Страница 7: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty pre Þlter will reduce the air volume and the cooling efÞciency To prevent from wasting electric energy please clean the pre Þlter every 2 weeks Please pay attention to the room temperature and air ßow direction when operating the unit for baby children and o...

Страница 8: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferenc...

Страница 9: ...h the front panel at three arrow portions as shown in Þgure and close it Cleaning and maintenance must be carried out when Þlter lamp lights Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air purifying Þlter as it may cause damage to the structure Please do not smell direct from source of Þlter NOTE O In case of removing the air purifying Þlters plea...

Страница 10: ...from the air purifying Þlter frame 2 Vacuum dust from the pre Þlter and air purifying Þlter using vacuum cleaner If there is too much dust rinse under running tap water and gently brush it with soft bristle brush Allow Þlters to dry in shade 3 O Re insert the air purifying Þlter to the Þlter frame Set the pre Þlter with FRONT mark facing front and slot them into the original state O After attachin...

Страница 11: ...he front panel with both hands to detach and attach it CAUTION O Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit O Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel O When the front panel is fully opened with both hands push the right ar...

Страница 12: ...able Is the plug of power line Þrmly plugged into the socket Please ensure no loose contact between them Cleaning and maintenance must be carried out only by qualiÞed service personnel Before cleaning stop operation and switch off the power supply CAUTION 3 MAINTENANCE BEFORE LONG OFF PERIOD O Run the unit by setting the operation mode to COOL the temperature to 32 C and the fan speed to HI for ab...

Страница 13: ...e odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the pre Þlter and the evaporator regularly must be cleaned to reduce the odor O Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your uni...

Страница 14: ... 14 MEMO ...

Отзывы: