PRECAUTIONS  DURING  OPERATION

O

 Do  not  attempt  to  operate  the  unit  with  wet  hands,  this  could  cause  fatal 

accident.

O

 When  operating  the  unit  with  burning  equipments,  regularly  ventilate  the 

room  to  avoid  oxygen  insuf

Þ

 ciency.

O

 Do  not  direct  the  cool  air  coming  out  from  the  air-conditioner  panel  to  face 

household  heating  apparatus  as  this  may  affect  the  working  of  apparatus 
such  as  the  electric  kettle,  oven  etc.

O

 Do  not  use  any  aerosol  or  hair  sprays  near  the  indoor  unit.  This  chemical

  can  adhere  on  heat  exchanger 

Þ

 n  and  blocked  the  evaporation  water 

ß

 ow

  to drain pan. The water will drop on tangential fan and cause water splashing 

out  from  indoor  unit.

O

 Please  ensure  that  outdoor  mounting  frame  is  always  stable, 

Þ

 rm  and 

without  defect.  If  not,  the  outdoor  unit  may  collapse  and  cause  danger.

O

 Do  not  splash  or  direct  water  to  the  body  of  the  unit  when  cleaning  it  as 

this  may  cause  short  circuit. 

O

 When operating the unit with the door and windows opened, (the room humidity is always above 

80%)  and  with  the  air  de

ß

 ector  facing  down  or  moving  automatically  for  a  long  period  of  time, 

water will condense on the air de

ß

 ector and drips down occasionally. This will wet your furniture. 

Therefore,  do  not  operate  under  such  condition  for  a  long  time.

O

 If  the  amount  of  heat  in  the  room  is  above  the  cooling  or  heating  capability  of  the  unit  (for  

example:  more  people  entering  the  room,  using  heating  equipments  and  etc.),  the  preset  room 
temperature  cannot  be  achieved.

O

 This appliance is not intended for use by young children or in

Þ

 rm persons unless they have been 

adequately  supervised  by  a  responsible  person  to  ensure  that  they  can  use  the  appliance  safely.

O

 Young  children  should  be  supervised  to  ensure  that  they  do  not  play  with  the  appliance.

O

 Do  not  climb  on  the  outdoor  unit  or  put  objects  on  it.

O

 Please  switch  off  the  unit  and  turn  off  the  circuit  breaker  during  cleaning, 

the  high-speed  fan  inside  the  unit  may  cause  danger.

O

 Turn off the circuit breaker if the unit is not to be operated for a long period.

C
A
U

T

I

O
N

O

 The  product  shall  be  operated  under  the  manufacturer  speci

Þ

 cation  and 

not  for  any  other  intended  use.

O

 Do  not  put  water  container  (like  vase)  on  the  indoor  unit  to  avoid  water 

dripping  into  the  unit.  Dripping  water  will  damage  the  insulator  inside  the 
unit  and  causes  short-circuit.

O

 Do  not  place  plants  directly  under  the  air 

ß

 ow  as  it  is  bad  for  the  plants.

!

Содержание RAK-18QXA

Страница 1: ... 1 RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA SPLIT TYPE AIR CONDITIONER INDOOR UNIT INDOOR UNIT RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA MODEL ...

Страница 2: ...l cord obtainable at authorized service parts centers W A R N I N G O During thunder storm disconnect and turn off the circuit breaker WARNING PRECAUTIONS DURING INSTALLATION O Do not reconstruct the unit Water leakage fault short circuit or Þre may occur if you reconstruct the unit by yourself O Please ask your sales agent or qualiÞed technician for the installation of your unit Water leakage sho...

Страница 3: ...ater will condense on the air deßector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time O If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved O This appliance is not inten...

Страница 4: ... DEPTH mm 198 MODEL NAME AND DIMENSIONS O Air purifying and deodorizing Þlters are not washable and reusable up to 20 times by using vacuum cleaner or water rinse under running tap water Type number for this air cleansing Þlter is SPX CFH22 Please use this number for ordering when you want to renew it O Air purifying Þlter should be cleaned every month or sooner if noticeable loading occurs When u...

Страница 5: ...ON INDICATOR TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work O By pressing the temporary switch the operation is done in previously set operation mode O When the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode TEMPOR ARY SWITCH TEMPORARY SWITCH Front panel Moveabl...

Страница 6: ...ere is a possibility panel coming off and falling down O Do not apply extra force on the front panel when it is opened up in the upright position Also frequent removal of the front panel from the front cover may cause damage CAUTION O Initially press the left and the right sides of the front panel and Þnally press the central portion until you hear a clicking sound Note O The recommended temperatu...

Страница 7: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty pre Þlter will reduce the air volume and the cooling efÞciency To prevent from wasting electric energy please clean the pre Þlter every 2 weeks Please pay attention to the room temperature and air ßow direction when operating the unit for baby children and o...

Страница 8: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferenc...

Страница 9: ...h the front panel at three arrow portions as shown in Þgure and close it Cleaning and maintenance must be carried out when Þlter lamp lights Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air purifying Þlter as it may cause damage to the structure Please do not smell direct from source of Þlter NOTE O In case of removing the air purifying Þlters plea...

Страница 10: ...from the air purifying Þlter frame 2 Vacuum dust from the pre Þlter and air purifying Þlter using vacuum cleaner If there is too much dust rinse under running tap water and gently brush it with soft bristle brush Allow Þlters to dry in shade 3 O Re insert the air purifying Þlter to the Þlter frame Set the pre Þlter with FRONT mark facing front and slot them into the original state O After attachin...

Страница 11: ...he front panel with both hands to detach and attach it CAUTION O Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit O Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel O When the front panel is fully opened with both hands push the right ar...

Страница 12: ...able Is the plug of power line Þrmly plugged into the socket Please ensure no loose contact between them Cleaning and maintenance must be carried out only by qualiÞed service personnel Before cleaning stop operation and switch off the power supply CAUTION 3 MAINTENANCE BEFORE LONG OFF PERIOD O Run the unit by setting the operation mode to COOL the temperature to 32 C and the fan speed to HI for ab...

Страница 13: ...e odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the pre Þlter and the evaporator regularly must be cleaned to reduce the odor O Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your uni...

Страница 14: ... 14 MEMO ...

Отзывы: