background image

–  11  –

EN

G

L

ISH

2.      Washable  Front  Panel

 

O

Remove the front panel and wash with clean water.
Wash it with a soft sponge.
After  using  neutral  detergent,  wash  thoroughly  with 
clean water.

 

O

When  front  panel  is  not  removed,  wipe  it  with  a  soft 
dry  cloth.  Wipe  the  remote  controller  thoroughly  with 
a soft dry cloth.

 

O

Wipe the water thoroughly.
If  water  remains  at  indicators  or  signal  receiver  of 
indoor unit, it causes trouble.

Method of removing the front panel.
Be  sure  to  hold  the  front  panel  with  both  hands  to 
detach and attach it.

!

CAUTION

 

O

Do not splash or direct water to the body of the unit when cleaning it as 
this may cause short circuit.

 

O

Never use hot water (above 40°C), benzine, gasoline, acid, thinner or a 
brush, because they will damage the plastic surface and the coating.

Removing  the  Front  Panel

 

O

When the front panel is fully opened with both 
hands,  push  the  right  arm  to  the  outside  to 
release  it,  and  while  closing  the  front  panel 
slightly, pull it out forward.

Attaching  the  Front  Panel

 

O

Move the projections of the left and right arms 
into the 

Flanges

 in the unit and securely insert 

them into the holes.

Projection

Hole

Flange

Arm

Содержание RAK-18QXA

Страница 1: ... 1 RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA SPLIT TYPE AIR CONDITIONER INDOOR UNIT INDOOR UNIT RAK 18QXA RAK 25QXA RAK 35QXA RAK 50QXA MODEL ...

Страница 2: ...l cord obtainable at authorized service parts centers W A R N I N G O During thunder storm disconnect and turn off the circuit breaker WARNING PRECAUTIONS DURING INSTALLATION O Do not reconstruct the unit Water leakage fault short circuit or Þre may occur if you reconstruct the unit by yourself O Please ask your sales agent or qualiÞed technician for the installation of your unit Water leakage sho...

Страница 3: ...ater will condense on the air deßector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time O If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved O This appliance is not inten...

Страница 4: ... DEPTH mm 198 MODEL NAME AND DIMENSIONS O Air purifying and deodorizing Þlters are not washable and reusable up to 20 times by using vacuum cleaner or water rinse under running tap water Type number for this air cleansing Þlter is SPX CFH22 Please use this number for ordering when you want to renew it O Air purifying Þlter should be cleaned every month or sooner if noticeable loading occurs When u...

Страница 5: ...ON INDICATOR TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work O By pressing the temporary switch the operation is done in previously set operation mode O When the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode TEMPOR ARY SWITCH TEMPORARY SWITCH Front panel Moveabl...

Страница 6: ...ere is a possibility panel coming off and falling down O Do not apply extra force on the front panel when it is opened up in the upright position Also frequent removal of the front panel from the front cover may cause damage CAUTION O Initially press the left and the right sides of the front panel and Þnally press the central portion until you hear a clicking sound Note O The recommended temperatu...

Страница 7: ...her with your wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty pre Þlter will reduce the air volume and the cooling efÞciency To prevent from wasting electric energy please clean the pre Þlter every 2 weeks Please pay attention to the room temperature and air ßow direction when operating the unit for baby children and o...

Страница 8: ...e used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferenc...

Страница 9: ...h the front panel at three arrow portions as shown in Þgure and close it Cleaning and maintenance must be carried out when Þlter lamp lights Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air purifying Þlter as it may cause damage to the structure Please do not smell direct from source of Þlter NOTE O In case of removing the air purifying Þlters plea...

Страница 10: ...from the air purifying Þlter frame 2 Vacuum dust from the pre Þlter and air purifying Þlter using vacuum cleaner If there is too much dust rinse under running tap water and gently brush it with soft bristle brush Allow Þlters to dry in shade 3 O Re insert the air purifying Þlter to the Þlter frame Set the pre Þlter with FRONT mark facing front and slot them into the original state O After attachin...

Страница 11: ...he front panel with both hands to detach and attach it CAUTION O Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit O Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating Removing the Front Panel O When the front panel is fully opened with both hands push the right ar...

Страница 12: ...able Is the plug of power line Þrmly plugged into the socket Please ensure no loose contact between them Cleaning and maintenance must be carried out only by qualiÞed service personnel Before cleaning stop operation and switch off the power supply CAUTION 3 MAINTENANCE BEFORE LONG OFF PERIOD O Run the unit by setting the operation mode to COOL the temperature to 32 C and the fan speed to HI for ab...

Страница 13: ...e odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the pre Þlter and the evaporator regularly must be cleaned to reduce the odor O Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your uni...

Страница 14: ... 14 MEMO ...

Отзывы: