background image

– 2 –

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

Pay special attention to signs of “     

Warning

” and “     

Caution

”. The “Warning” section contains matters which,

if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.

The sign indicate the following meanings.

Please keep this manual after reading.

!

SAFETY PRECAUTION

WARNING

PRECAUTIONS DURING INSTALLATION

Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct
the unit by yourself.

Please ask your sales agent or qualified technician for the installation
of your unit. Water leakage, short circuit or fire may occur if you install
the unit by yourself.

Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.

A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.

Do not install near location where there is flammable gas. The outdoor
unit may catch fire if flammable gas leaks around it.

Please ensure smooth flow of water when installing the drain hose.

CAUTION

!

!

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

PRECAUTIONS DURING OPERATION

Avoid an extended period of direct air flow for your health.

W

A
R

N

I

N
G

!

Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
occur if you continue to operate the unit under abnormal situation.

Please contact your agent for maintenance. Improper self maintenance may cause
electric shock and fire.

Please contact your agent if you need to remove and reinstall the unit. Electric
shock or fire may occur if you remove and reinstall the unit yourself improperly.

Do not put objects like thin rods into the panel of blower and suction side
because the high-speed fan inside may cause danger.

During thunder storm, disconnect and turn off the circuit breaker.

Do not use any conductor as fuse wire, this could cause fatal accident.

!

Make sure to connect earth line.

Indicates the instructions that must be followed.

The sign in the figure indicates prohibition.

W

A
R

N

I

N
G

!

Содержание RAC-R10C-1

Страница 1: ... 23 ...

Страница 2: ...he unit Without a circuit breaker the danger of electric shock exists Do not install near location where there is flammable gas The outdoor unit may catch fire if flammable gas leaks around it Please ensure smooth flow of water when installing the drain hose CAUTION PRECAUTIONS DURING SHIFTING OR MAINTENANCE PRECAUTIONS DURING OPERATION Avoid an extended period of direct air flow for your health W...

Страница 3: ...air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be achieved Do not climb on the outdoor unit or put objects on it Pl...

Страница 4: ... Light indicator showing the operating condition Refer page 5 HORIZONTAL DEFLECTOR VERTICAL DEFLECTOR AIR OUTLET Refer page 12 REMOTE CONTROL Send out operation signal to the indoor unit So as to operate the whole unit Refer page 6 780 700 750 280 570 570 210 210 280 DRAIN PIPE Condensed water drain to outside CONNECTING CORD AIR INLET BACK LEFT SIDE AIR OUTLET DRAIN PIPE Condensed water drain to ...

Страница 5: ...ly set operation mode When the operation is done using the temporary switch after the power source is turned off and turn on again the operation is done in automatic mode OPERATION INDICATOR SUPER LAMP This lamp lights during super operation OPERATION LAMP This lamp lights during operation TIMER LAMP This lamp lights when the timer is working Power switch TEMPORARY SWITCH Press Temporary Switch No...

Страница 6: ... Do not drop it on the floor and protect it from water If you press the FUNCTION selector button during operation the air conditioner may stop for about 3 minutes for protection before you can start it again unless you turn off and on again the power source You can use the remote controller by fixing it on the wall with the accessory parts Before fixing it make sure the unit can be controlled by t...

Страница 7: ... the preset temperature in the Automatic mode Device will receive the setting by a beep You can slightly adjust the room temperature 1 CONDITION OF AUTOMATIC OPERATION The selected mode of operation will not change during the operation even though the room temperature change Over 27 C COOL 16 27 C FUNCTION 27 C Slightly lower than the room temperature LOW FAN SPEED When the difference of room temp...

Страница 8: ... SILENT SILENT SILENT SUPER 2 Temperature changing Increase temperature when it is too cool Decrease temperature when it is too hot 2 SILENT SILENT SUPER This mode cannot change fan speed SUGGESTION Cooling capacity will be decreased 20 25 at silent mode This mode is suitable to be used after room temperature comes to setting temperature If the room humidity is more than 80 when using silent opera...

Страница 9: ...re Setting Up up when too cool DOWN unable to down because this setting temperature is the lowest 16 C 2 3 FAN SPEED SETTING Press to change fan speed as the below sequence HIHI HIGH MED LOW When operate in this mode can not use TIMER RESERVATION mode STOP SUPER MODE Press to stop this mode and change the mode to other Press to stop this mode and also turn off the unit 4 Fan speed can not operated...

Страница 10: ...art Stop button next time STOP 2 ROOM TEMPERATURE SETTING Up Down The cooling operation does not start if the temperature setting is higher than the current room temperature If the device uses for cooling when the humudity is very high over 80 at indoor some dew may form and drop on the air outlet grill of cooling unit Cooling 25 28 C Dehumidify 25 26 C 3 FAN SPEED SETTING Every time you press the...

Страница 11: ...will change according to the below sequence The value change quicker if you keep pressing the button ON Timer Reservation 0 5 1 0 1 5 9 5 10 11 12 0 5 hour interval 1 hour interval 1 Press the Cancel button As the time settings are stored in remote controller memory you only have to press the Reserve button in order to use the same setting next time CANCELLATION of Timer Reservation 2 Press the Re...

Страница 12: ...he vertical air deflector as shown in the figure and adjust the conditioned air to the left and right If the AUTO SWING button is pressed once the horizontal air deflector swings up and down If the button is pressed again the deflector stops in its current position Several seconds about 6 seconds may be required before the deflector starts to move Use the horizontal air deflector within the adjust...

Страница 13: ...2 Install the new batteries The direction of the batteries should match the marks in the case 1 Do not use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 or 3 months 3 The batteries must be of the AAA type CAUTION Push and pull to the direction of arrow ...

Страница 14: ...wake up time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and old folks who h...

Страница 15: ...to be used for a long period of time please switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 8W in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket OFF Interference From Electrical Products Inverter type fluorescent ...

Страница 16: ...it Cleaning and maintenance must be carried out only by qualified service personal Before cleaning stop operation and switch off the power supply CAUTION CAUTION Do not bend the air cleansing deodorizing filter as it may cause damage to the structure NOTE In case of removing the air cleansing deodorizing filters please follow the above procedures The cooling capacity is slightly weakened and the c...

Страница 17: ... brush it with soft bristle brush Allow filters to dry in shade 3 Re insert the air cleansing and deodorizing filter to the filter frame Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and close it CAUTION Do not wash with hot water at more than 40 C The filter may shrink W...

Страница 18: ...urface and the coating Removing the Front Panel When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly pull it out forward Attaching the Front Panel Move the projections of the left and right arms into the Flanges in the unit and securely insert them into the holes Projection Flange Hole 3 MAINTENANCE AT BEGINN...

Страница 19: ...ur plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal whi...

Страница 20: ...ng cycle 2 Slight rubbing noise from the fan casing which is cooled and then gradually warmed as operation stops The odor will possibly be emitted from the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So please clean the air filter and the evaporator regularly to reduce the odor Please contact your sales agent immediately if the air con...

Страница 21: ...ularly when the room light is dimmed a slight brightness fluctuation may occur This is of no consequence The conditions of the local Power Supply Companies are to be observed Minimum Maximum Indoor Dry bulb C 21 32 Wet bulb C 15 23 Outdoor Dry bulb C 21 43 Wet bulb C 15 26 Note Avoid to use the room air conditioner for cooling operation when the outside temperature is below 21 C 70 F The recommend...

Страница 22: ... 22 MEMO ...