– 49 –
Notes:
1. Condition for entering Cool Dashed Mode: When fan is set at ‘Hi’ or ‘Auto’ Mode or when the fan speed is changed to ‘Hi’ or ‘Auto’ during cooling operation and temperature difference
between indoor temperature and setting tempe SHIFTC has a corresponding compressor rpm (calculated value in Table 2) larger than CMAX.
2. Cool Dashed will release when: (i) a maximum 25 minutes is elapsed after Cool Dashed Mode was started; (ii) room temperature less than cooling setting tempe SHIFTC - 1°C,
then maximum Cool Dashed time will be revised to 20 minutes; (iii) Thermo OFF (the compressor does not go through the steady speed period but it starts by fuzzy control).
3. During Cool Dashed operation, Thermo OFF temperature = setting tempe SHIFTC - 3°C. After Thermo OFF, operation continues in fuzzy control.
4. The compressor minimum ‘ON’ time and ‘OFF’ time is 3 minutes.
5. During normal cooling mode, CMAX will be maintained until 60 minutes when room temperature less than CLMXTP and no time constrain when room temperature is CLMXTP and above.
6. If the fan speed set to ‘Med’ mode by remote control, maximum compressor rpm = CJKMAX.
7. If the fan speed set to ‘Lo’ mode by remote control, maximum compressor rpm = CBEMAX.
8. If the fan speed set to ‘Silent’ mode by remote control, maximum compressor rpm = CSZMAX.
9. During Cool Dashed, when room temperature reaches setting temperature - 1°C, compressor rpm = actual rpm x DWNRATEC.
Table 2 TCMAX
1.66
2300
2.00
2300
2.33
2300
2.66
2800
3.00
2800
3.33
2800
3.66
3300
4.00
3300
4.33
3300
4.66
3800
5.00
3800
6.00
4300
6.33
4300
6.66
4800
7.00
4800
7.33
4800
7.66
5300
8.00
5300
8.33
5300
8.66
5800
9.00
5800
9.33
5800
9.66
6300
10.00
6300
10.33
6300
10.66
6800
11.00
6800
Temperature
difference
Calculated compressor
rpm
Содержание RAC-50YH7
Страница 22: ... 21 SHIFT VALUE ADJUSTMENT ...
Страница 32: ... 31 Note 1 200mm or more servicing space is required above the outdoor unit ...
Страница 35: ... 34 INDOOR UNIT OUTDOOR UNIT A A A A WIRING DIAGRAM MODEL RAS 80YH5A RAC 80YH5 ...
Страница 36: ... 35 CIRCUIT DIAGRAM Remote Control ...
Страница 37: ... 37 CIRCUIT DIAGRAM MODEL RAS 80YH5A ...
Страница 38: ... 39 CIRCUIT DIAGRAM MODEL RAC 80YH5 ...
Страница 40: ... 42 MODEL RAC 80YH5 MAIN P W B ...
Страница 41: ... 43 MAIN P W B NF P W B CAPA P W B ...
Страница 46: ... 51 ...
Страница 49: ... 57 ...
Страница 83: ... 92 SELF DIAGNOSIS LIGHTING MODE DD0002204A ...
Страница 85: ... 94 2 Outdoor unit does not operate but receives remote infrared signal ...
Страница 88: ... 97 CHECKING THE REMOTE CONTROLLER ...
Страница 93: ... 102 16 ...
Страница 103: ...PM NO 0413E Printed in Malaysia RAS 80YH5A RAC 80YH5 ...