– 5 –
Figure showing the installation of Indoor and Outdoor unit
ab
ou
t 0
.5m
above 100mm
g above 500 mm
h above 200 mm
above 200 mm
above 300 mm
Maximum pipe length 30m
Minimum pipe length 5m
above 200 mm
( )
g give clearance
as wide as possible
must not bend
above 2300 mm
above
200 mm
above 50mm
above 100mm
Be sure to
completely
seal any
gap with
putty.
●
The difference in height
between the indoor and
outdoor unit should be kept
max 10m.
●
The connecting pipe, no
matter big or small, should
all be insulated with
insulation pipe and then
wrapped with vinyl tape. (The
insulator will deteriorate if it
is not wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
inner diameter ø 16mm
In case the pipe length is more than 8m, add refrigerant R22 at 40 gram per every meter exceeds. However,
pipe length shall not exceed 30m.
CAUTION
0301E (30CH6) pg 1-5