– 43 –
Set
temperature
Start/stop switch
Sleep key
Operation lamp
Timer lamp
60 minutes
5 deg down
LO (sleep operation)
Set circulation
velocity
Set
temperature
Start/stop switch
Sleep key
Operation lamp
Sleep key
Timer lamp
60 minutes
5 deg down
LO (sleep operation)
Set circulation
velocity
Start/stop switch
Thermostat signal
Preheating signal
Fan relay H
Fan relay L
Fan relay S
Power relay
Hot keep lamp
2 sec
T
3 minutes
30 sec 30 sec
15sec 30 sec 30 sec
"Strong" circulation
2 sec
T
E
15 sec
15 minutes-T
E
30 sec
30 sec
Completion
Defrosting
start
30 sec
30 sec
2 sec
10 sec
Start/stop switch
Defrosting signal
Preheating signal
Fan relay H
Fan relay L
Fan relay S
Power relay
Stick relay
External fan relay
Reversing valve relay
Heater relay
Operation lamp
Hot keep lamp
2 sec
10 sec
T
A
30 sec 60 sec
3 minutes
T
A
30 sec 60 sec
T
B
T
C
15 sec
Indoor heat exchanger
thermistor temperature
T
1
Fan relay H
Power relay
Stick relay
Outside fan relay
Operation lamp
Fan relay S
Power relay
Stick relay
Outside fan relay
Operation lamp
Min. 3 minutes
Set circulation velocity
Set circulation velocity
Set
temperature
Start/stop switch
Sleep key
Operation lamp
Timer lamp
60 minutes
60 minutes
2 deg up
LO (sleep operation)
Control function
Operation mode
Fan
Cooling
Sensor dehumidification
Heating
Automatic
• Sleep operation is executed
for each operation mode.
• Sleep operation is executed
for each operation mode.
• At the time of heating
operation mode, the same
operation as for heating
is executed.
• Defrosting of each operation
mode is executed.
7
• The operation is
switched OFF
at the set time.
8
Preheating
operation
9
Defrosting
(including automatic
fresh defrosting).
Notes:
• 60 minutes after the sleep key is switched on, sleep operation
is started.
• When the sleep key is switched on during OFF timer operation,
the OFF timer will be canceled.
• When the sleep key is switched on during OFF timer operation, the OFF timer will be cancelled.
• When the sleep key is switched on during ON after a timer reservation, sleep operation will be started.
Notes:
• Even when the preheating signal is not given as input, heating operation is started when
3 minutes have passed for T.
• Preheating operation is executed at the time of operation start and after completion
of defrosting, and at all other times, there is no operation, independent of the preheating signal.
TA
(Reverse cycle defrosting)
10 min.
min.
TB
(Silencing period)
30 sec
TC
(Cycle balancing time)
30 sec
TE
(Defrosting prohibition
time)
50 min.
min.
+0
-5
+0
-1
• For the time TE after start of heating operation, defrosting will not be
executed even when the defrosting signal is given as input.
• When the reserve cycle defrosting TA has continued for the time
shown in the table on the left, the operation advances to TB and TC
independent of the defrosting signal.
• When the power relay becomes ON after expiration of the time TE,
defrosting will be started immediately with input of the defrosting signal.
• Once defrosting has been completed, the defrosting signal is not
accepted for the time TE.
• When a defrosting signal has been given as input at the time of stop
by means of the start/stop switch or at the time of OFF timer count-up,
defrosting is executed before operation stop.
• The defrosting signal is not accepted at the time of overload input.
Sensor dehumidification
Cooling strong
No.
•
The set temperature
after sleep shift in
sensor dehumidification
operation is limited
by 16
°
C.
Automatic
Heating
Fan
Sensor
dehumidification
Cooling
Heating
Cooling
Yes
Yes
Yes
Yes
Yes
Yes (automatic)
NO
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Cooling/Heating
Item
Operation switching
Temporary switch
Service switch
Nice temperature reservation
Automatic fresh defrosting
Defrosting
Pd cut 1
Pd cut 2
Pd cut 3
Heating load reduction
External fan relay
Reversing valve relay
Reversing valve lock protection
Sleep circuit
Heater operation at the time of sensor
dehumidification
Automatic blowing direction
Filter sign
Wireless mode
Item
Cooling, Sensor
16
17.6
ON temperature
dehumidification
24
25.6
Thermostat
(Thermostat relay)
32
33.6
operation
power relay
Heating
16
19.6
(
°
C)
24
27.6
32
35.6
Differential (
°
C)
0.33
–
–
Low-temperature
(T1)
ON (
°
C)
1.0
defrosting
Reset (
°
C)
12.0
Preheating
Reset (
°
C)
17.0
ON (
°
C)
15.0
–
–
Pd cut 1
(T3)
ON (
°
C)
56.0
(T4)
Reset (
°
C)
52.0
Pd cut 2
(T6)
ON (
°
C)
66.0
(T7)
Reset (
°
C)
57.0
(T5) Fan Relay H
[
Original (
°
C)
58.0
Pd cut 3
(T8)
ON (
°
C)
62.0
(T9)
Reset (
°
C)
57.0
Table 1 Specifications
Table 2 Sensor operation values
Other detailed specifications
1.
When the room temperature rises
within 3 minutes after thermostat
OFF during cooling operation with
automatic velocity, the blowing
velocity changes in the order of
S
→
L
→
H in the same way as
at the time of thermostat ON.
2.
In case of Tele. control input during
stopped ON timer, operation will
be started at that time and the timer
will be cleared.
3.
In case of Tele. control input during
operation of the OFF timer, the
operation will be stopped at that
time and the timer will be cleared.
4.
Even when operation stop is
executed at the time of outside fan
OFF by overload, automatic fresh
defrosting will not be executed.
5.
In case of switching to “Heating”
during
“Automatic” heating
operation, the operation will be
continued as it is when the
thermostat is ON. 3 min delay will
not be entered. However, the set
room temperature and the blowing
velocity will be according to the
remote control signal. The same
applies for switching from “Heating”
to “Automatic” heating.
6.
In case of switching from “Sensor
dehumidification” operation to
“Cooling”, as it is when the
thermostat is ON. 3 min delay will
not be entered. However, the set
room temperature and the blowing
velocity will be according to the
remote control signal.
The same applies for switching
from
“Cooling” to “Sensor dehumidifica-
tion”. The same also applies for
“Automatic” sensor dehumidifica-
tion, cooling “Sensor dehumidifica-
tion”, “Cooling”.
7.
The filter sign lights after operation
of the indoor fan for 200 hours. The
time is cleared when power switch
set to OFF and ON again.
8.
After entry into trouble mode (when
the indication lamp is flashing), the
rapid feed mode can not be
changed.
9.
When operation by nice
temperature reservation is
executed during sleep operation,
normal operation will be continued,
and the advance time becomes the
temperature difference between the
set temperature without sleep shift
and the room temperature.
10.
The 50 minutes of defrosting
prohibition are counted from
Thermostat ON after start/stop
switch ON. When the thermostat
is OFF at the time of start/stop
switch ON, the 60 minutes will be
counted from the time of thermostat
ON. The initial OFF time is not
counted. Counting starts when the
thermostat becomes ON, and the
count then continues even if the
thermostat becomes OFF.
11.
In case of switching from “Heating”
the reversing valve is held for 3
minutes.
12.
The defrosting signal is not
accepted with overload input, and
the operation becomes as shown
below when the overload input
disappears.
(1)
When previously the
defrosting signal existed
without overload input,
defrosting will start
immediately.
(2)
In cases other than the
above, defrosting will be
executed with a defrosting
signal in the condition
without overload input.
0301E (30CH6) pg 43
16/12/05, 2:47 PM