– 57 –
Air does not come out when
starting a heating operation.
Q6
It is not a trouble. The fan is
stopped to avoid cold wind.
A6
When starting the operation,
the heat exchanger is cold
and, therefore, the fan is
stopped.
Wait 2–3 minutes.
Heating operation
Air does not come out
sometimes while in a heating
operation.
Defrosting is on. Wait for 5–
10 minutes unit the outdoor
unit is defrosted.
A7
The fan speed is set to “HI”
or “MED” but the heating
operation starts with a LO fan
speed.
Q8
The heating operation
starts with a LO fan speed
for 30 seconds. If the fan
speed is set to HI, the
operation starts with LO fan
speed, followed by MED
fan speed for 30 seconds
and then by HI fan speed.
A8
Q7
The operation stops during
a heating operation while the
room temperature is set at
“30”.
Q9
If a heating operation is per-
formed when the exterior
temperature is high, the op-
eration may stop to protect
the equipment.
A9
The outdoor fan does not
move at a heating operation
by the service switch.
It is not a trouble.
When heating, the outdoor
fan is stopped to avoid ex-
cessive pressure rise.
A10
Q10
Heating has been turned off by the main
operation but the “Hot keep lamp” lights and
the outdoor unit operations.
Q11
Auto fresh defrosting
“Auto fresh defrosting” operates. When
stopping the operation, whether the outdoor
unit is frosted or not is checked and, if in the
affirmative, defrosting is performed before
stopping the operation.
A11
0301E (30CH6) pg 47-68