– 33 –
MODEL
RAC-30CH6
COMPRESSOR MODEL
2JD514E
PHASE
SINGLE
RATED VOLTAGE
220 ~ 240 V
RATED FREQUENCY
50 Hz
LOCKED ROTOR CURRENT
65.2 A
POLE NUMBER
2
COMPRESSOR MOTOR
Compressor Motor Specifications
CONNECTION
20
°
C
(68
°
F)
75
°
C
(167
°
F)
( )
RESISTANCE VALUE
!
CAUTION
When the Air Conditioner has been operated for a long time with the capillary tubes clogged or crushed or
with too little coolant, check the color of the refrigerant oil inside the compressor. If the color has been
changed conspicuously, replace the compressor.
RM = 1.022
RA = 2.142
RM = 1.243
RA = 2.605
EXTERNAL OVERLOAD RELAY
INTERNAL PROTECTOR
NO
YES
ORANGE
RM
WHITE
PROTECTOR
RA
RED
CAPACITOR
R (ORANGE)
S (RED)
C (WHITE)
0301E (30CH6) pg 30-34
16/12/05, 2:40 PM
33