13ー22
11. Timer lamp blinking: blinking 12 times
[Situation] The timer blinks 12 times and the product will not run.
[Estimated failure locations]
Erroneous connection in the indoor-outdoor connection line (F cable)
Wire break or poor insertion of the indoor-outdoor connection line (F cable)
Electrical parts in the outdoor unit (communication circuit, power circuit error)
Communication error due to noise in other home electronics
This does not constitute a failure in the air-conditioner
[Cautions] When lines 1 and 2 of F cable are erroneously connected (crossed), the product may not
enter self-diagnosis display mode. If the self-diagnosis memory stores data about "timer
lamp blinked 12 times", then, just in case, check if the F cable is not erroneously connected.
[Diagnosis flow]
Initiating troubleshooting
Is the F cable connection free from errors?
Yes
Yes
Yes
Yes
No
No
No
No
Correct the F cable connection.
Is the CN
securely inserted into
the outdoor board?
Correct the connector.
Press the START/STOP button on the remote control
unit and start the product.
Are terminals 1 and 2of the terminal board of the
electrical parts of the outdoor unit subjected to
Take measurements within 3 minutes after remote
control operation.
Check the electrical parts of the
outdoor unit.
Are terminals 1 and 2 of the terminal board of the electrical
parts of the indoor unit subjected to
220-230V ?
Take measurements within 3 minutes after remote control
operation.
Double-check the F cable for erroneous connection,
wire break and poor insertion, and correct the
nonconforming parts.
Replace the "indoor control P.W.B".
1 . Timer lamp blinking: blinking 13 times
[Situation] The timer lamp blinks 13 times and the product will not run.
[Estimated failure location]
EEPROM, microcomputer
[Diagnosis flow]
Replace the "indoor control P.W.B".
Forget to connect CN27 of outdoor P.W.B
AC 220-230V ?
AC
2
27
Содержание RAC-25FXB
Страница 38: ...RAC 25 35FXB MODEL 6ー2 ...
Страница 39: ...RAC 50FXB MODEL 6ー3 ...
Страница 65: ...11ー6 10 10 10 10 10 R901 R904 R641 R907 R908 R694 R902 R695 R741 R740 R642 DSW1 DSW1 R903 R905 R906 ...
Страница 68: ...11ー9 L N 300 330 A B Main parts C021 C023 500 450V RAC 25 35FXB MODEL ...
Страница 72: ...11ー13 5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 ...
Страница 74: ...11ー15 2A Fuse DC300 330V 7 7 1 ...
Страница 75: ...11ー16 2A DC300 330V ...
Страница 76: ...11ー17 L N 300 330 A B MODEL RAC 50FXB ...
Страница 77: ...11ー18 300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 ...
Страница 81: ...11ー22 5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 ...
Страница 83: ...11ー24 2A Fuse DC300 330V 7 1 7 ...
Страница 84: ...11ー25 2A DC300 330V ...
Страница 94: ...13ー7 91 ...
Страница 95: ...13ー8 IC531 IC531 IC531 ...
Страница 96: ...13ー9 SELF DIAGNOSIS LIGHTING MODE RAC 25 35FXB MODEL ...
Страница 97: ...13ー10 SELF DIAGNOSIS LIGHTING MODE RAC 50FXB MODEL ...
Страница 119: ...14ー1 40 ...
Страница 120: ...14ー2 Please set the DIP switch No 6 to ON accordingly Refer to page 59 ...
Страница 121: ...14ー3 59 ...
Страница 122: ...14ー4 ...
Страница 131: ...Printed in Japan HRT TC NO 0842E RAF 25RXB RAC 25FXB RAF 35RXB RAC 35FXB RAF 50RXB RAC 50FXB ...