12ー1
Automatic operation
During heating, I turned off the
product by using the START/STOP
button. But the “operation lamp” is
blinking and the outdoor unit is
running.
Q1
Auto-fresh defrost
The product stops during heating
even though it is set to “30
℃
”.
Q3
The product begins with a “Low”
during heating even though set to
“Hi” or “Med”.
Q2
The product sometimes fails to
produce a wind during heating.
Q1
Heating operation
The indoor unit produces a noise that
goes “shaaahhh” during
dehumidification.
Q1
Dehumidification
The compressor sometimes
stops during cooling.
Q1
Cooling operation
A1
Check if the heat
exchanger of the indoor
unit is covered with frost.
Wait for 3 to 4 minutes
until the frost disappears.
A1
That is a noise produced by refrigerant flowing through
the pipe.
A1
Defrosting is in progress. Wait 5 to 10 minutes until
the dew on the outdoor unit disappears.
At the first of the heating, the product will run for 30 seconds
with a
“Low”.
When set to “Hi”, the product will begin with a
“Low”
operation, producing a “Med” for 30 seconds, and then
switch to “Hi”.
A2
A3
When heating is conducted despite the high outdoor
temperature, the product may stop to protect its
equipment.
The “auto-fresh defrost” should be working. When
stopped, the product will check its outdoor unit for frost
and, if there is any frost, conduct defrosting and then
stop operating.
A1
Q1
A1
Cooling when the room
temperature is low may
cause the heat exchanger
of the indoor unit to gather
frost.
SERVICE CALL Q&A
2
A
2
Q
A
Q
Cold air comes out during a
dehumidifying operation.
The operation does not stop even by
setting the temperature higher than
room temperature on the remote
controller.
To improve the dehumidification efficiency performs
quiet fan operation. Therefore the air is cold and it is
not a malfunction.
It sets to perform dehumidifying operation by setting
the temperature slightly lower than remote controller
setting.
3
3
RAF-25/35/50RXB
MODEL
Содержание RAC-25FXB
Страница 38: ...RAC 25 35FXB MODEL 6ー2 ...
Страница 39: ...RAC 50FXB MODEL 6ー3 ...
Страница 65: ...11ー6 10 10 10 10 10 R901 R904 R641 R907 R908 R694 R902 R695 R741 R740 R642 DSW1 DSW1 R903 R905 R906 ...
Страница 68: ...11ー9 L N 300 330 A B Main parts C021 C023 500 450V RAC 25 35FXB MODEL ...
Страница 72: ...11ー13 5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 ...
Страница 74: ...11ー15 2A Fuse DC300 330V 7 7 1 ...
Страница 75: ...11ー16 2A DC300 330V ...
Страница 76: ...11ー17 L N 300 330 A B MODEL RAC 50FXB ...
Страница 77: ...11ー18 300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 ...
Страница 81: ...11ー22 5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 ...
Страница 83: ...11ー24 2A Fuse DC300 330V 7 1 7 ...
Страница 84: ...11ー25 2A DC300 330V ...
Страница 94: ...13ー7 91 ...
Страница 95: ...13ー8 IC531 IC531 IC531 ...
Страница 96: ...13ー9 SELF DIAGNOSIS LIGHTING MODE RAC 25 35FXB MODEL ...
Страница 97: ...13ー10 SELF DIAGNOSIS LIGHTING MODE RAC 50FXB MODEL ...
Страница 119: ...14ー1 40 ...
Страница 120: ...14ー2 Please set the DIP switch No 6 to ON accordingly Refer to page 59 ...
Страница 121: ...14ー3 59 ...
Страница 122: ...14ー4 ...
Страница 131: ...Printed in Japan HRT TC NO 0842E RAF 25RXB RAC 25FXB RAF 35RXB RAC 35FXB RAF 50RXB RAC 50FXB ...