![Hitachi RAC-18WPB Скачать руководство пользователя страница 77](http://html.mh-extra.com/html/hitachi/rac-18wpb/rac-18wpb_service-manual_139606077.webp)
When power is supplied, the microcomputer reads the data in IC531 (E PROM) and sets the preheating
2
activation value and the rating and maximum speed of the compressor, etc. to their initial values.
Data of self-diagnosis mode is stored in IC531; data will not be erased even when power is turned off.
Fig. 6-1
The temporary switch is used to operate the air conditioner temporarily when the wireless remote control
is lost or faulty.
The air conditioner operates in the previous mode at the previously set temperature. However, when the
power switch is set to OFF, it starts automatic operation.
Fig. 7-1
TEMPORARY SW
MICROCOMPUTER
R405
SW211
Temporary
switch
0V
0V
C405
R663
5V
6. Initial Setting Circuit (IC531)
7. Temporary Switch Circuit
R403
5V
R406
C404
90
1
2
3
4
5
0
0 10 20 30 40
8. Room Temperature Thermistor Circuit
A room temperature thermistor circuit is shown in Fig. 8-1.
According to room temperature, the voltage of point becomes as it is shown in Fig.8-2.
Microcomputer
Room Temperature
Thermistor
V
oltage of point
(V)
(
㷄
)
Room temperature
Room
temperature input
Fig. 8-1
Fig. 8-2
䃢
A
0V
0V
5V
2
0
1
0
10 20 30 40
3
4
5
-10
R402
C403
R407
91
9. Heat Exchanger Thermistor Circuit
Heat exchanger temperature is noticed inside the room
(1) Preheating
(2) Low-temperature defrosts at cooling
and
dehumidification operation time.
(3) Not working of reversing valve or detection of opening of heat exchange thermistor is controlled.
According to heat exchange temperature, the voltage of point becomes as it is shown in Fig. 9-2.
Heat exchanger
thermistor
Microcomputer
Heat exchanger
input
Fig. 9-1
Fig. 9-2
V
oltage of point (V)
㷄
Heat temperature ( )
䃢
A
100
77
Содержание RAC-18WPB
Страница 50: ...WIRING DIAGRAM RA RAC 18 25 35WPB K 18 25 35 50PPB RAC 5 WPB 0 50 ...
Страница 52: ...CIRCUIT DIAGRAM MODEL RAK 18 25 35 50PPB 52 WIRED REMOTE CONTROL SEND POWER FOR CLEANNESS ...
Страница 53: ...MODEL RA C 18 25 35 WPB 53 ...
Страница 54: ...MODEL RAC 50WPB 54 ...
Страница 67: ...MODEL RAK 18 25PPB RAC 18 25WPB INDOOR UNIT INDOOR UNIT 67 ...
Страница 68: ...COOLING CYCLE INDOOR UNIT OUTDOOR UNIT HEATING CYCLE INDOOR UNIT OUTDOOR UNIT MODEL RAK 35PPB RAC 35WPB 68 ...
Страница 78: ...10 10 10 10 10 R901 R904 R641 R907 R908 R694 R902 R695 R741 R740 R642 DSW1 DSW1 R903 R905 R906 78 ...
Страница 81: ...L N 300 330 Main parts L N C021 C022 37 5 420V RAC 18 25 35WPB 81 1 5 ...
Страница 85: ...5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 85 ...
Страница 86: ...6 Electric expansion valve circuit 48 47 46 45 13 14 15 16 4 3 2 1 68 67 66 65 RED 14 12 10 7 6 1 8 6 1 6 2 86 ...
Страница 87: ...2A Fuse DC300 330V 7 7 1 87 ...
Страница 88: ...2A DC300 330V 88 ...
Страница 89: ...L N 300 330 L N 50WPB 89 ...
Страница 90: ...300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 90 ...
Страница 94: ...5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 94 ...
Страница 96: ...2A Fuse DC300 330V 7 1 7 96 ...
Страница 97: ...2A DC300 330V 97 ...
Страница 108: ...108 109 ...
Страница 110: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 18 25 35WP B 110 ...
Страница 111: ...SELF DIAGNOSIS LIGHTING MODE MODEL RAC 50WP B 111 ...
Страница 131: ...57 131 ...
Страница 132: ...Please set the DIP switch No 6 to ON accordingly Refe to page r 78 132 ...
Страница 133: ...78 133 ...
Страница 134: ...134 ...
Страница 148: ...HITACHI RAK 18PPB RAC 18WPB RAK 25PPB RAC 25WPB HHAW NO 0080E RAK 35PPB RAC 35WPB RAK 50PPB RAC 50WPB 3 148 ...