63
V
ar
io
us
F
un
ct
io
ns
Door Alarm
If any door is kept opened for 1 minute or more, it is notified with sound or light.
All the doors have the Door Alarm function. (However, for R-WX670J type, R-WX620J type, no Door Alarm is installed in the Upper Freezer.)
●
While the indicator lamp is blinking on the display area, the Control Panel remains inactive upon touching. Close the door before starting operation.
●
Door alarm rings after 30 seconds when the door has been opened only in case the power “Energy Saving” mode set. However the indicator blinks
after 1 minute of the opening.
Duration when door is
open
1 minute
2 minutes
From 3 minutes onward
Alarm sound
Long beep (3 beeps)
Long beep (5 beeps)
Long beep (continuously), Louder
Display area
Blinking
Blinking
Blinking
For operation
Light ON
Light ON
Light ON
Notice
Door Alarm and volume adjustment of the operation sound
Touch
button on the Control Panel to turn
on the indicator lamp.
All indicator lamps turn on, and then the current settings are displayed.
Press down
button for 3 seconds or more
until the preset sound is heard.
The volume level of the operation sound is changed from “Standard” to “Louder”
or “Sound off” . Repeat the change of settings to set the operation sound you
like (see the table shown below). The sound is set to “Standard” at the time of
purchase.
1
2
●
It is impossible to adjust the volume level of
either door alarm or operation sound only.
●
When the Door Alarm is disabled, characters
on the Control Panel no longer blink.
●
Even if the volume level is set to “Sound off” ,
the alarm of the Ice Maker Cleaning is raised
and the operation sound is heard when the
Auto Door is set to “ON” .
●
When connecting/disconnecting the power
plug or after recovering from electric power
failure, it will return to the standard setting
where the Door Alarm sounds.
Notice
You can set the sound level of the alarm louder or no alarm sound.
Volume level
Standard
Louder
Sound off
Standard
Preset sound
−
2 long beeps
Long beep
2 beeps
(At the time of purchase)