56
VARIOUS FUNCTIONS
(CONTINUED)
Set the condensation prevention heater to MIN.
(Swing partition)
Setting the condensation prevention heater to MIN saves energy.
When dew is formed in the swing partition, set it to the standard.
The temperature settings for the swing partition can be adjusted by three levels (1 to 2), and level 2 is the most energy saving.
Swing partition
●
The setting will be returned to the standard when the power plug is disconnected and connected or power failure recovery takes place.
Notice
Setting the swing partition
Open the door of the Lower Freezer Compartment.
Press down
button 3 seconds or more until the preset sound is heard.
Settings of condensation prevention heater will be changed. Repeat the change of settings to set the operation sound you like
(See the table shown above).
Close the door of the Lower Freezer Compartment.
1
3
2
Fine adjustment of the temperature
(Refrigerator Compartment / Freezer Compartment)
Temperature settings for Refrigerator and Freezer Compartments can be more finely adjusted by 11 levels.
Open the door of the Lower
Freezer Compartment.
Push
or
button to make an
adjustment.
Each time you touch the button, the corresponding indicator lamp
changes in the order shown below.
Usually it is recommended to use it at the setting of “
■■
” .
Press down
button for 5
seconds or more until 1 beep is
heard.
Close the door of the Lower
Freezer Compartment.
Follow the operations shown in Step 1, 2 and 3.
2 beeps sound and you can set the temperature by normal step (3 levels).
1
4
2
3
To
cancel
MIN setting of the heater
Standard
MIN setting
level 1
MIN setting
level 2
Standard
Preset sound
−
Long beep
Long beep (2 beeps)
2 beeps
(Factory setting)
Triple Power Deodorizing Effect
A combination of 3 types of deodorizing materials leads to deodorizing various odorous substances in the refrigerator including 4
major odors such as sulfur, nitrogen, aldehyde and oxidization odors. Activities of bacteria collected by the filter are also restricted.
Deodorant filter has the effect of sterile filtration.
●
Testing laboratory: Boken Quality Evaluation Institute, a general incorporate foundation
●
Test method: Film contacting method (JIS Z 2801)
●
Name of the part used for treatment: Filter
●
Sterilization method: applying oxidation catalyst to the filter
●
Target: bacteria collected by the filter
●
Test result: sterilization effect of 99 % after 24 hours by using a filter only. This does not always have effect on the entire refrigerator or foods.
(
Lighting
Blinking
Turned off
)
Indication
lamp
Setting
MIN and under MIN.
MID.
MAX. MAX and more