-31-
•
Disassembly and reassembly of Nail Guide, Nail Stopper (A), Nail Stopper (B), etc
Nose
[43]
Shaft Ring
[112]
Nail Guide
[121]
Nail Guide Shaft
[53]
Nail Guide Cover
[117]
Nail Stopper (B)
[124]
Cover
[118]
Stopper Spring
[125]
Shaft Ring
[112]
Sleeve (B)
[127]
Nylock Hex. Socket Hd. Bolt
M4 x 12
[128]
Nylock Hex. Socket Hd.
Bolt M4 x 10
[126]
Nail Stopper (A)
[122]
Nail Stopper Spring
[123]
O-Ring (P-4)
[113]
Spring
[120]
Guide Lock
[119]
Fold back the end for
reassembly.
4. Disassembly and reassembly of Nail Guide, Nail Stopper (A), Nail Stopper (B), etc
[Tools required]
•
Long-nose pliers
•
Flat-blade screwdriver
•
Hex. bar wrench (3 mm)
(1) Disassembly
•
Grasp the Nail Guide Shaft
[53]
with long-nose pliers or a similar tool, lower it, and then pull it out.
You can then remove Nail Guide
[121]
and other components together.
•
Remove the Nylock Hex. Socket Hd. Bolt M4 x 12
[128]
and Nylock Hex. Socket Hd. Bolt M4 x 10
[126]
by using the Hex. bar wrench (3 mm). You can then detach the Nail Guide Cover
[117]
, Nail
Stopper Spring
[123]
, Stopper Spring
[125]
, and
Cover [118]
.
•
Remove the Shaft Ring
[112]
of the Guide Lock
[119]
by using the flat-blade screwdriver, and then pull
out Guide Lock
[119]
. You can remove Nail Stopper (A)
[122]
and Nail Stopper (B)
[124]
.
(2) Reassembly
Conduct reassembly by reversing the disassembly procedure, but note the following:
•
Completely clean the claw groove of the Nail Guide
[121]
prior to reassembly.
•
Completely engage the Nail Stopper Spring
[123]
and Stopper Spring
[125]
with the convex portions of
Nail Stopper (A)
[122]
and Nail Stopper (B)
[124]
prior to reassembly.
•
After reassembly, press Nail Stopper (A)
[122]
and Nail Stopper (B)
[124]
respectively with your fingers
and make sure both return smoothly.
•
Assemble the Nail Guide Shaft
[53]
with its chamfered portion facing up.
•
Fit the Shaft Ring
[112]
into the groove of the Nail Guide Shaft
[53]
.
•
Fold back the end of the Cover
[118]
and fit it into the convex portion of the Magazine
[132]
.