Drop Away (DA) Current Value __________
9. Calculate the DA percentage of actual PU (DA%). It must be equal to or greater
than 80% of the actual PU value noted in Step 6. (DA% = Step 8 Value
÷
Step 6
Value
×
100).
10. When the track energy is reduced to 1.7 volts or 0.028 amp, the vane must have
touched the lower roller stop.