L100-M Inverter
19
L100-M Series inverters add the following 6 options to the 15 option codes for standard
L100 inverter intelligent inputs:
Input Function Summary Table
Option
Code
Terminal
Symbol
Function Name
Description
20
STA
START
(3-wire interface)
ON
Starts the motor rotation
OFF
No change to present motor status
21
STP
STOP
(3-wire interface)
ON
Stops the motor rotation
OFF
No change to present motor status
22
F/R
FWD, REV
(3-wire interface)
ON
Selects the direction of motor rotation: ON =
FWD. While the motor is rotating, a change of
F/R will start a deceleration, followed by a
change in direction.
OFF
Selects the direction of motor rotation:
OFF =REV.
While the motor is rotating, a change of F/R will
start a deceleration, followed by a change in
direction.
27
UP
Remote Control
UP Function (motor-
ized speed pot.)
ON
Accelerates (increases output frequency) motor
from current frequency
OFF
No change to output frequency
28
DWN
Remote Control
DOWN Function
(motorized speed
pot.)
ON
Decelerates (decreases output frequency) motor
from current frequency
OFF
No change to output frequency
31
OPE
Operator Control
ON
Forces the source of the output frequency setting
(A_01) and the source of the RUN command
(A_02) to be from the digital operator
OFF
Source of output frequency set by (A_01) and
source of run command set by (A_02) is used