2. Read command (Note: 1 to 7 and SUM need to be transformed into ASCII code)
1
2
3
4
5
6
7
Item
STX
STATUS
ID NO.
AREA
ADDRESS
RELATIVE
NO.
DATA
ETX SUM
MODE
02
00
FF
81
04
00
00
00
03
21
POLARITY
02
00
FF
81
0F
00
00
00
03
10
TRIGGER
SOURCE
02
00
FF
81
05
00
00
00
03
20
OUTPUT SIGNAL
02
00
FF
81
06
00
00
00
03
1F
PRESET
02
00
FF
81
08
00
00
00
03
1D
SHUTTER SPEED
VARIABLE VALUE
02
00
FF
81
11
00
00
00
03
23
DATA BIT
02
00
FF
81
14
00
00
00
03
20
VD / FVAL
02
00
FF
81
15
00
00
00
03
1F
HD / LVAL
02
00
FF
81
16
00
00
00
03
1E
GAIN
02
00
FF
81
0C
00
00
00
03
12
BLACK LEVEL
02
00
FF
81
17
00
00
00
03
1D
VERTICAL 2 PIXEL ADDITION
02
00
FF
81
13
00
00
00
03
21
MODE
02
00
FF
81
1E
00
00
00
03
0F
START
02
00
FF
81
1F
00
00
00
03
0E
PARTIAL SCAN
WIDTH
02
00
FF
81
20
00
00
00
03
23
TEST PATTERN
02
00
FF
81
50
00
00
00
03
20
The reading data from the Slave is based on "4. Comms command data format(2)" of "Remote control" (page 14).