ADJUSTMENTS
1) FM Discriminator
Measuring instrument and condition.
2) Voltage of covering (Reference)
Measuring instrument and condition.
Input Terminal Output Terminal Measuring Instrument
Frequency
Adjust
Reading
FM Antenna
* R22
DC Balance Meter
98.1MHz
T4
0±30mV
1kHz, 60 dBµ
22.5kHz dev.
Band
Destination
Frequency
Specification
Note
Limit (V)
Average (V)
FM
50 kHz step
87.50 MHz
1.3 - 3.7
2.3
[E, EBS, W,WUN]
108.00 MHz
6.0 - 9.0
7.5
AM
10 kHz step
520 kHz
0.9 - 1.2
1.0
[W,WUN]
1,710 kHz
6.0 - 9.0
7.5
9 kHz step
522 MHz
0.9 - 1.2
1.0
[E, EBS, W, WUN]
1,611 kHz
6.0 - 9.0
7.5
*
R22
DC balance meter
TEST PT
BL1
R51
Содержание HTA-DD1E