REV0 10.02.15
-H8-15-
Bind-head
screw
mirror
Bind-head
screw
mirror
CCD Sensor
P/K
#22
Scanner ASSY
⑪
Unscrew 2 bind-head screws on the Scanner
ASSY
⑫
Disconnect connector (J38) attached to the
CCD Sensor Connector (J40F) and the Main
P/K ASSY (CPS619 P/K) and remove Scanner
ASSY.
For instructions, please refer to “8.3.3 Replacing
the DRV P/K (CPS614 P/K)”
Caution:
・
Do not damage the cable
・
The CCD Sensor P/K (CPS615) should not
touch the mirror
・
Attach the connector straight into the device
⑬
Attach the maintenance part to the Mirror Motor
Cable and take the reverse steps to reassemble it
To attach the Mirror Motor Connector (MMF)
please read the previous page carefully. Attach it
straight onto the device
Check if the CCB Sensor Connector is attached. If it
is not attached properly, it may cause light density
errors
Check cable route “8.3.4” and make sure there is
enough distance between the Motor Cable and the
Ultra Sonic Sensor Cable. Noise between the 2 could
cause errors in the Ultra Sonic Sensor
⑭
Run the Auto Calibration Test.(refer to
Chapter6)
#23 DRV P/K ASSY(CPS614 P/K
)
J38
Mirror
Position of screw
Mirror
Mirror Motor Connector
(MMF)
#22
Scanner ASSY
CCD Sensor Connector
(J40F)
Position of screw
CAUTION
CAUTION
CAUTION
CAUTION
Содержание HT-4139-28
Страница 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Страница 2: ......
Страница 11: ... H2 5 2 5 Block Diagram ...
Страница 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Страница 35: ...REV0 10 02 15 H7 2 ...
Страница 63: ...REV0 2010 02 15 H7 30 ...
Страница 89: ...REV0 10 02 15 H8 26 ...