![Hitachi HT-4139-28 Скачать руководство пользователя страница 111](http://html.mh-extra.com/html/hitachi/ht-4139-28/ht-4139-28_maintenance-manual_145876111.webp)
REV0 10.02.15
-H8-48-
8.3.34 Replacing the DC Fan
Tools Needed: Magnetic Philips Screwdriver (No.2)
■
Replacing the Package Cover DC Fan
①
Read “8.3.2 Replacing Main P/K ASSY (CPS619 P/K)”
①~④
and remove the Package Cover.
②
Unscrew 2 screws on the DC Fan and Disconnect the connector J7. Remove the DC Fan from the device.
③
Take the reverse steps to attach the DC Fan
screw
#51 DC Fan
screw
Connector J7
Package Cover
Air Direction
■
Replacing the Main Base (R) ASSY DC Fan
①
Read “8.3.5 Replacing the Scanner ASSY”
①~⑨
and make the scanner in the same state as the picture
below
②
Unscrew 2 screws on the DC Fan, and disconnect the connector J7. Remove the DC Fan from the device.
Take the reverse steps to attach the DC Fan.
Check cable route “8.3.4” and make sure there is enough distance between the Motor Cable and the Ultra
Sonic Sensor Cable. Noise between the 2 could cause errors in the Ultra Sonic Sensor
screw
#52 DC Fan
screw
8.3.35 Replacing the Anti-vibration rubber
Tools Needed: Magnetic Philips Screwdriver (No.2)
①
Read “8.3.24 Replacing the Stepping Motor” and replace the Anti-vibration rubber
②
Take the reverse step to attach the Anti-vibration rubber.
Содержание HT-4139-28
Страница 1: ...HT 4139 28 48 Scanner Maintenance Manual ...
Страница 2: ......
Страница 11: ... H2 5 2 5 Block Diagram ...
Страница 22: ...REV0 10 02 15 H3 10 Lens Mirror Motor Mirror No 1 Mirror No 3 Mirror No 2 ...
Страница 35: ...REV0 10 02 15 H7 2 ...
Страница 63: ...REV0 2010 02 15 H7 30 ...
Страница 89: ...REV0 10 02 15 H8 26 ...