4. CHECKING THE HARDWARE STATUS
4-30
4.5.4 Objects in the extended MIB for HF-W
In order to acquire the hardware status of this equipment from a remote device, use the
extended MIB for HF-W. This subsection provides a list of objects defined in the
extended MIB for HF-W and a description of those objects.
(1) Objects related to the hardware conditions and settings
Table 4-12 shows a list of the objects related to the hardware status and a description
of those objects. The object ID of each object is obtained by either replacing the
following “x” with the object in the following table or replacing the following “y”
with the object number in the table.
Object ID: .iso.org.dod.internet.private.enterprises.Hitachi.systemExMib.
hfwExMib.hfwRasStatus.x (x is an object in the table below)
or
.1.3.6.1.4.1.116.5.45.1.y (y is an object number in the table below)
Table 4-12 Objects Related to the Hardware Status
(1/2)
No.
Object
Object
number
Description
Description of the values
1
hfwFan
1
Fan condition group
-
2
hfwFan.fanNumber
1.1
The number of monitored
fans
-
3
hfwFan.fanTable.fanEntry.fanIndex
1.2.1.1
Index number of fanEntry
-
4
hfwFan.fanTable.fanEntry.fanName
1.2.1.2
Fan name
PS fan: Power fan
Front fan: Front fan
CPU fan: CPU fan
5
hfwFan.fanTable.fanEntry.fanStatus
1.2.1.3
Fan condition
1: Normal
2: Error
6
hfwTemp
2
Temperature condition
group
-
7
hfwTemp.tempNumber
2.1
Number of monitored
temperatures
-
8
hfwTemp.tempTable.TempEntry.tempIndex
2.2.1.1
Index number of tempEntry
-
9
hfwTemp.tempTable.TempEntry.tempName
2.2.1.2
Name of the temperature to
bemonitored
Internal temperature:
Temperature inside the chassis
10 hfwTemp.tempTable.TempEntry.tempStatus
2.2.1.3
Temperature condition
1: Normal
2: Error
11 hfwHdd
3
Drive condition
group
-
12 hfwHdd.hddNumber
3.1
Number of monitored drive
bays
-
13 hfwHdd.hddTable.hddEntry.hddIndex
3.2.1.1
Index number of hddEntry
-
Содержание HF-W6500 45/40
Страница 1: ...WIN 63 0088 02 ...
Страница 2: ...WIN 63 0088 02 ...
Страница 21: ...This page is intentionally left blank ...
Страница 35: ...This page is intentionally left blank ...
Страница 79: ...4 CHECKING THE HARDWARE STATUS 4 26 5 In the SNMP Service Properties window click Apply ...
Страница 91: ...This page is intentionally left blank ...
Страница 105: ...This page is intentionally left blank ...
Страница 137: ...This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 163: ...This page is intentionally left blank ...