6. LIBRARY FUNCTIONS
6-1
CHAPTER 6 LIBRARY FUNCTIONS
A user application can get and control the hardware status of this equipment by using the RAS
library.
For information about the hardware specifications of the RAS external contacts interface (optional)
described in this chapter and the usage of each contact, see “HF-W6500 Model 45/40
INSTRUCTION MANUAL (manual number WIN-62-0064)”.
6.1 RAS Library Interface
6.1.1 Overview
This chapter describes the interface to the functions provided by the RAS library.
Table 6-1 shows a list of RAS library functions.
Table 6-1 RAS Library Functions
No.
Function name
Use
DLL
1
BSSysShut
Shuts down the equipment.
w2kras.dll
2
WdtControl
Retriggers, gets the status of, and stops the watchdog timer.
3
GendoControl
Opens and closes the general purpose external contact output
(GENDO0). (for backward compatibility)
4
GendoControlEx
Opens and closes the general purpose external contact outputs
(GENDO0, GENDO1, and GENDO2).
5
GetGendi
Gets the status of the general purpose external contact input
(GENDI). (for backward compatibility)
6
GetGendiEx
Gets the status of the general purpose external contact inputs
(GENDI, GENDI0, GENDI1, and GENDI2).
7
MconWriteMessage
Records a specified message (characters) in this equipment’s
own log files.
8
GetMemStatus
Acquires the condition of the memory built into this equipment.
9
GetHddPredict
Acquires the failure prediction status of the drive. (for backward
compatibility)
10 hfwDiskStat
Acquires the status of the drive.
hfwras.dll
11 hfwRaidStat
Acquires the RAID status.
12 RaidStat
Acquires the status of the drives in the RAID. (for backward
compatibility)
hfwraid.dll
13 SetStCode7seg
Outputs an application status code on the status display digital
LEDs.
ctrl7seg.dll
14 TurnOff7seg
Clears an application status code on the status display digital
LEDs.
15 SetMode7seg
Configures the status display mode of the status display digital
LEDs.
Those functions mentioned above are offered in the DLLs (w2kras.dll, hfwras.dll,
hfwraid.dll,and ctrl7seg.dll).
Содержание HF-W6500 45/40
Страница 1: ...WIN 63 0088 02 ...
Страница 2: ...WIN 63 0088 02 ...
Страница 21: ...This page is intentionally left blank ...
Страница 35: ...This page is intentionally left blank ...
Страница 79: ...4 CHECKING THE HARDWARE STATUS 4 26 5 In the SNMP Service Properties window click Apply ...
Страница 91: ...This page is intentionally left blank ...
Страница 105: ...This page is intentionally left blank ...
Страница 137: ...This page is intentionally left blank ...
Страница 147: ...This page is intentionally left blank ...
Страница 163: ...This page is intentionally left blank ...