Rev. 1.0, 03/01, page 86 of 280
7.5
Program/Erase Protection
There are three kinds of flash memory program/erase protection; hardware protection, software
protection, and error protection.
7.5.1
Hardware Protection
Hardware protection refers to a state in which programming/erasing of flash memory is forcibly
disabled or aborted because of a transition to reset, subsleep mode or standby mode. Flash
memory control register 1 (FLMCR1), flash memory control register 2 (FLMCR2), and erase
block register 1 (EBR1) are initialized. In a reset via the
RES
pin, the reset state is not entered
unless the
RES
pin is held low until oscillation stabilizes after powering on. In the case of a reset
during operation, hold the
RES
pin low for the
RES
pulse width specified in the AC
Characteristics section.
7.5.2
Software Protection
Software protection can be implemented against programming/erasing of all flash memory blocks
by clearing the SWE bit in FLMCR1. When software protection is in effect, setting the P or E bit
in FLMCR1 does not cause a transition to program mode or erase mode. By setting the erase
block register 1 (EBR1), erase protection can be set for individual blocks. When EBR1 is set to
H'00, erase protection is set for all blocks.
7.5.3
Error Protection
In error protection, an error is detected when CPU runaway occurs during flash memory
programming/erasing, or operation is not performed in accordance with the program/erase
algorithm, and the program/erase operation is aborted. Aborting the program/erase operation
prevents damage to the flash memory due to overprogramming or overerasing.
When the following errors are detected during programming/erasing of flash memory, the FLER
bit in FLMCR2 is set to 1, and the error protection state is entered.
•
When the flash memory of the relevant address area is read during programming/erasing
(including vector read and instruction fetch)
•
Immediately after exception handling excluding a reset during programming/erasing
•
When a SLEEP instruction is executed during programming/erasing
The FLMCR1, FLMCR2, and EBR1 settings are retained, however program mode or erase mode
is aborted at the point at which the error occurred. Program mode or erase mode cannot be re-
entered by re-setting the P or E bit. However, PV and EV bit setting is enabled, and a transition
can be made to verify mode. Error protection can be cleared only by a power-on reset.
Содержание H8/3670F-ZTAT HD64F3670
Страница 2: ...Rev 2 0 03 01 page ii of xxiv ...
Страница 4: ...Rev 2 0 03 01 page iv of xxiv ...
Страница 14: ...Rev 2 0 03 01 page xiv of xxiv ...
Страница 20: ...Rev 1 0 03 01 page xx of xxiv ...
Страница 24: ...Rev 1 0 03 01 page xxiv of xxiv ...
Страница 78: ...Rev 1 0 03 01 page 54 of 280 ...
Страница 112: ...Rev 1 0 03 01 page 88 of 280 ...
Страница 248: ...Rev 1 0 03 01 page 224 of 280 ...