6 - 29
Adjustment > Adjustment Procedure
6-4-7 Matrix
Preparation:
1) Point at light box without chart,
fi
lling the
screen.
2) Prepare the C12 light balancing
fi
lter (step-up
rings): Attach it during adjustment.
Procedure:
1) Choose MATRIX.
2) Click the EXECUTE button start
adjustment.
The progress status can be con
fi
rmed using
the PROGRESS STATUS dialog.
3) The ATTACH THE FILTER dialog will
appear during setup.
Attach the C12 light balancing
fi
lter over
the lens of DVD video camera/recorder, and
then click the OK button in ATTACH THE
FILTER dialog.
Note:
When the "CANNOT OPEN THE MATRIX.
DAT FILE" dialog appears during adjustment,
click the OK button, and then create the
reference data, referring to "6-1 Creating
Reference Data".
The "CANNOT OPEN THE MATRIX.DAT
FILE" dialog will appear when reference data
has not been created.
OK
CANNOT OPEN THE MATRIX.DAT FILE
ERROR
!
CANNOT OPEN THE MATRIX.DAT FILE
dialog
4) The REMOVE THE FILTER dialog will
appear during setup.
Remove the C12 light balancing
fi
lter from
the lens of DVD video camera/recorder, and
then click the OK button in REMOVE THE
FILTER dialog.
After that, the ATTACH THE FILTER dialog
and REMOVE THE FILTER dialog may
occasionally appear: Reattach the C12 light
balancing
fi
lter and remove it each time.
5) Click the OK button in
dialog to restore the ADJUST MENU screen.
ADJUST MENU screen
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
MODEL NAME:
××××
EXECUTE
RETURN
CONNECTION
ADJUST MENU
DATA INITIALIZE
SAMPLING PULSE
AUTO IRIS CONTROL
MATRIX
CHROMA GAIN
AUTO FUCUS
SPOT NOISE
LCD
VIDEO LEVEL
BURST LEVEL
2
1
MATRIX
PLEASE WAIT A MOMENT
ADJUSTMENT FINISHED dialog
FINISHED
ADJUSTMENT FINISHED.
OK
5
ATTACH THE FILTER dialog
REMOVE THE FILTER dialog
OK
Attach The Filter.
CHECK
!
3
OK
Remove The Filter.
CHECK
!
4
PROGRESS STATUS dialog