Model
DSP-90A6N
DSP-110A6N
DSP-90VA6N
DSP-110VA6N
Air Compr
essor
Discharge Pressure
psi
(MPa)
100
(0.69)
125
(0.86)
100
(0.69)
125
(0.86)
100
(0.69)
125
(0.86)
100
(0.69)
125
(0.86)
Intake air Press./Temp.
℉ (℃)
Atmospheric Pressure, 32 to 104 (0 to 40)
Type of compressed gas
−
Air
Capacity@rated
pressure 60Hz
cfm
(m
3
/min)
636/544
(18.0/15.4)
724/611
(20.5/17.3)
636/544
(18.0/15.4)
724/611
(20.5/17.3)
Maximum motor
shaft power
HP (kW)
160 (120)
185 (138)
160 (120)
185 (138)
No. of Compression Stage
−
2-Stage
Driving Method
−
Gear Driven
Motor Starting Method
−
Star-Delta
Inverter
Discharge Air Pipe Connection
inch
2 (flange connection)
Discharge Air Temperature
℉ (℃)
Atmospheric Tempe 27(15), or less
Oil Quantity
gal (L)
6.9 (26) (Not filled)
Capacity Control System
−
On-Off line, 0% or 100% capacity, 2-step Variable Speed + Purge + Auto stop/restart
Oil Cooler/Aftercooler/
Intercooler
−
Corrugated Fin Structure with Aluminum Slitted-Fin
Main Motor
Nominal Output
HP (kW)
135 (100)
160 (120)
135 (100)
160 (120)
Type
−
Totally Enclosed Motor
Voltage
V
460
Rated Current
A
150
175
150
175
Frequency
Hz
60
Number of Pole
−
2
Insulation Class
−
F
Cooling Fan Motor
Rated Output
HP (kW)
2×2 (1.5×2)
Type
−
PN-604-15H
Voltage
V
460
Maximum Current
A
2.5
3.4
Frequency
Hz
60
Number of Pole
−
4
Insulation Class
−
E
Approximate Weight
lbs (kg)
5,250 (2,380)
5,600 (2,540)
5,470 (2,480)
5,580 (2,530)
External Dimensions
(W×D×H)
inches
(mm)
84.6×59.8×77.8
(2,150
×
1,520
×
1,975)
NOTE: (1) Capacity is measured according to ISO 1217, Third Edition, Annex C.
(2) Earth leakage circuit breaker is out of scope of supply from Hitachi.
(3) DSP series air compressors are not designed, intended or approved for breathing air applications.
(4) Pressures are indicated as the gauge pressure.
(5) Install the air compressor indoors and avoid flammable and corrosive environment, moisture and dust.
(6) Use 3.5-4.5 ton duty fork truck for transportation of this air compressor.
(7) Hitachi may make improvements and/or changes in the appearance and/or specifications described in this publication at
anytime without notice.
122
15. STANDARD SPECIFICATIONS
Air-Cooled