Oil Filling Port
Oil Level Gauge
●
Indicates the operation control section.
(
3.1
)
●
Power ON
→
The Power light ON.
●
Start: Press the
START
button.
→
Start light ON.
●
Stop: Press the
UNLOAD STOP
button.
→
The compressor unloads for 5 minutes and then
stops.
→
Start light OFF.
●
Power OFF:
→
Power light OFF.
2.3 Daily Operating Components
Controls on the Instrument Panel
Aftercooler and Intercooler - Condensate Drain Valve
Lubricating Oil
Oil Level Gauge
1
2
3
4
●
Verify that air containing condensate is discharged
intermittently from the intercooler and aftercooler
drain ports.
The higher temperature and humidity, the more condensate
is produced. Condensate may not be produced on the
intercooler side during winter.
[Fixed speed type]
Intercooler
drain port
Aftercooler
drain port
Intercooler
drain port
Aftercooler
drain port
Control pipe filter
drain port
●
Verify that the oil stays between the upper and
lower red lines of the oil level gauge during the
operation.
Oil level might be higher than upper line during air
compressor stopping due to oil returning from the cooler
and pipings.
10
2. GENERAL DESCRIPTION [Daily Operating Components]
Oil: Use genuine Hitachi GL-68 DSP Compressor Oil.
Replace the oil every 8,000h operating hour or every
2-year, whichever comes earlier.
UP/
DOWN
+/−
AUTO
MONITOR
MENU
SET
SELECT/WIDE
2
RUNNING CONTROL
START
REMOTE
1
FUNC
[×
10h
]
ALARM
STR
REMOTE
RUNNING MODE
AUTO START
POWER
LOAD
RESET
SHUTDOWN
STOP
MONITOR
UNLOAD STOP