English
25
(2) Regarding the temperature of the battery
The temperatures for batteries are as shown in the
Table 2
, and batteries that have
become hot should be cooled for a while before being recharged.
Table 2
Recharging ranges of batteries
Batteries
Temperatures at which the battery can be recharged
BCL1015
0°C – 50°C
(3) Regarding recharging time
Depending on the combination of the charger and batteries, the charging time will become
as shown in
Table 3.
Table 3
Charging time (At 20°C)
Charger
Battery
UC10SL2
BCL1015
Approx. 30 min.
NOTE
The charging time may vary according to temperature and power source voltage.
4. Disconnect the charger’s power cord from the receptacle.
5. Hold the charger
fi
rmly and pull out the battery.
NOTE
Be sure to pull out the battery from the charger after use, and then keep it.
CAUTION
○
If the battery is charged while it is heated because it has been left for a long time in
a location subject to direct sunlight or because the battery has just been used, the
pilot lamp of the charger lights for 1 second, does not light for 0.5 seconds (o
ff
for
0.5 seconds). In such a case,
fi
rst let the battery cool, then start charging.
○
When the pilot lamp
fl
ickers (at 0.2-second intervals), check for and take out any
foreign objects in the charger’s battery connector. If there are no foreign objects, it
is probable that the battery or charger is malfunctioning. Take it to your authorized
Service Center.
○
Since the built-in micro computer takes about 3 seconds to con
fi
rm that the battery
being charged with UC10SL2 is taken out, wait for a minimum of 3 seconds before
reinserting it to continue charging. If the battery is reinserted within 3 seconds, the
battery may not be properly charged.
0000Book_DS10DAL_ChS.indb 25
0000Book_DS10DAL_ChS.indb 25
2015/4/22 13:32:29
2015/4/22 13:32:29