Monitoring operating status
2-3
Hitachi Compute Rack 210H User’s Guide
ERROR LED
The Baseboard Management Controller (BMC), an onboard management
controller of the system unit, turns on the ERROR LED on the front of the system
unit if a hardware error occurs, such as a HDD error, a fan error, a power supply
error, and others.
The sensors having a threshold are lit up in the Critical State (a critical state of
the system unit). But do not turn on in the Uncritical State (a state in which a
component has a failure under redundancy).
MAINTENANCE LEDs
You can choose what is displayed as the operation status from the event code,
the POST code and the power consumption using a SERVICE switch.
A combination of ON/OFF selections of MODE0 LED, MODE1 LED, and SERVICE
LED determines what is currently displayed.
A combination of ON/OFF selections of MODE0 LED, MODE1 LED, and the
SERVICE LED determines what the MAINTENANCE LEDs indicate as follows:
Table 2-2: What the MAINTENANCE LEDs indicate
SERVICE LED
MODE0 LED
MODE1 LED
What the MAINTENANCE
LEDs indicate
Off Off Off
Event code
On Off On
POST code
Off On On
Power consumption
When you press a SERVICE switch, the MAINTENANCE LEDs change as follows.
Figure 2-2: MAINTENANCE LEDs indicate pressing of SERVICE switch
Pressing of SERVICE
switch (number: press
count)
Содержание Compute Rack 220H
Страница 14: ...1 6 Before operation Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 54: ...4 4 Operational precautions Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 76: ...2 Acronyms and Abbreviations Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 77: ...Index Index 1 Hitachi Compute Rack 210H User s Guide Index ...
Страница 78: ...Index 2 Index Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 79: ...Hitachi Compute Rack 210H User s Guide ...
Страница 80: ......