6-10
Troubleshooting
Hitachi Compute Rack 210H User’s Guide
Error message
Description
Action
Memory Error. Please check the SDRAM
connection. If problems persist contact Tech
Support.
A cache memory error has occurred in
the disk array controller.
(*1)
Memory Error. Detected Unsupported RAID
Controller Memory.
Contact Tech support.
A cache memory error has occurred in
the disk array controller.
(*1)
Unrecoverable Error. Please check the
SDRAMconnection.
If problems persist contact Tech Support.
A cache memory error has occurred in
the disk array controller.
(*1)
This is a TEST message.
Press any key to ignore it, or wait 5 seconds.
No further action is required.
Press any key to continue, or C to load the
configuration utility.
Test message
(*1)
This firmware is an ALPHA version.
It has not completed all validation.
The firmware is of alpha version.
(*1)
This firmware is a BETA version.
It has not completed all validation.
The firmware is of beta version.
(*1)
This firmware is a TEST version.
It has not completed any validation.
The firmware is of test version.
(*1)
The firmware version inconsistency was
detected. The adapter was recovered, but
cached data was lost.
Press any key to continue or press C to load
the configuration utility.
Firmware version inconsistency has
been detected.
(*1)
Firmware Failed Validation. Adapter needs to
be refreshed.
Firmware version inconsistency has
been detected.
(*1)
The most recent configuration command
could not be committed and must be retried.
Press any key to continue, or press C to load
the configuration utility.
The disk array configuration information
has been cleared or missing.
(*1)
Previous configuration cleared or missing.
Importing configuration created on X/Y
X:Y
Press any key to continue or press C to load
the configuration utility.
The disk array configuration information
has been cleared or missing.
(*1)
An enclosure was found that contains both
SAS and SATA drives, but this controller does
not allow mixed drive types in a single
enclosure.
Correct the problem and restart your system.
Press any key to continue or press C to load
the configuration utility.
The disk array controller is working with
illegal parameters.
(*1)
SAS drives were detected, but this controller
does not support SAS drives.
Remove the SAS drives and restart your
system.
Press any key to continue or press C to load
the configuration utility.
The disk array controller is working with
illegal parameters.
(*1)
Содержание Compute Rack 220H
Страница 14: ...1 6 Before operation Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 54: ...4 4 Operational precautions Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 76: ...2 Acronyms and Abbreviations Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 77: ...Index Index 1 Hitachi Compute Rack 210H User s Guide Index ...
Страница 78: ...Index 2 Index Hitachi Compute Rack 210H User s Guide This page is intentionally left blank ...
Страница 79: ...Hitachi Compute Rack 210H User s Guide ...
Страница 80: ......