19
English
Table
1
Indications of the pilot lamp (UC18YGSL)
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Overheat
standby
Blinks
Lights for 1 second. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
Charging
impossible Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o
ff
for 0.1 seconds)
Malfunction in the
battery or the charger
Indications of the pilot lamp (UC18YRSL)
Pilot lamp
(red)
Before
charging
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
While
charging
Lights
Lights continuously
Charging
complete
Blinks
Lights for 0.5 seconds. Does not light for 0.5
seconds. (o
ff
for 0.5 seconds)
Charging
impossible Flickers
Lights for 0.1 seconds. Does not light for 0.1
seconds. (o
ff
for 0.1 seconds)
Malfunction in the
battery or the charger
Pilot lamp
(green)
Overheat
standby
Lights
Lights continuously
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).
(2) Regarding the temperatures of the rechargeable
battery
The temperatures for rechargeable batteries are as
shown in the
Table
2
, and batteries that have become
hot should be cooled for a while before being recharged.
Table
2
Recharging ranges of batteries
Temperatures at which the battery can be recharged
0°C – 50°C
(3) Regarding recharging time
Table
3
shows the recharging time required according
to the type of battery.
Table
3
Charging time (At 20°C)
Charger
Battery
UC18YGSL
UC18YRSL
BSL1430
Approx. 90 min.
Approx. 45 min.
BSL1830
Approx. 90 min.
Approx. 45 min.
BSL1440
Approx. 120 min. Approx. 60 min.
BSL1840
Approx. 120 min. Approx. 60 min.
NOTE
The recharging time may vary according to the ambient
temperature.
4.
Disconnect
the
charger’s
power
cord
from
the
receptacle.
5.
Hold
the
charger
fi
rmly
and
pull
out
the
battery.
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
Regarding
electric
discharge
in
case
of
new
batteries,
etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an extended
period is not activated, the electric discharge might be
low when using them the
fi
rst and second time. This is
a temporary phenomenon, and normal time required for
recharging will be restored by recharging the batteries
2 – 3 times.
How
to
make
the
batteries
perform
longer
(1) Recharge the batteries before they become completely
exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the electric
current, the battery may be damaged and its life will
become shorter.
000Book_CG14DSDL_EE.indb 19
000Book_CG14DSDL_EE.indb 19
2013-1-24 18:25:56
2013-1-24 18:25:56
Содержание CG 14DSDL
Страница 158: ...158 1 2 3 4 5 000Book_CG14DSDL_EE indb 158 000Book_CG14DSDL_EE indb 158 2013 1 24 18 26 09 2013 1 24 18 26 09 ...
Страница 160: ...160 000Book_CG14DSDL_EE indb 160 000Book_CG14DSDL_EE indb 160 2013 1 24 18 26 09 2013 1 24 18 26 09 ...
Страница 161: ...161 000Book_CG14DSDL_EE indb 161 000Book_CG14DSDL_EE indb 161 2013 1 24 18 26 09 2013 1 24 18 26 09 ...
Страница 162: ...162 000Book_CG14DSDL_EE indb 162 000Book_CG14DSDL_EE indb 162 2013 1 24 18 26 09 2013 1 24 18 26 09 ...