Maintenance log and tracing functions
3–5
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
How to read detailed error log codes
You can obtain detailed information on the error from an error message
(EX_CMDIOE and/or EX_CMDRJE) collected in a command log by referring
to a detailed code, sense code, and sub-code. Each code can be collected
from an error message or error log displayed at the time of command
execution. Figure 3-2 shows an example of each code displayed in the error
message. See Refer to
, or
for each code displayed in the error log.
•
Figure 3-2: Error Message Example
for detailed information about the error indicated by the
collected detailed code, sense code and sub-code
A command log is output to the side of an instance that has executed a
command. An error log is output to an instance on the primary volume side
or the secondary volume side depending on the type of the command
irrespective of whether the instance that has executed the command is on
the primary volume side or the secondary volume side. When an error
occurs during the execution of the command, examine the error cause by
looking at the error logs of both local instance (an instance that has
executed the command) and the remote instance. Examples of the
decisions, to which of the local instance and the remote instance the error
log corresponding to the command log is output, are shown in
.
•
The error log corresponding to the command log can be found out using a
time when an error occurs as a key.
Table 3-4: Command Log and Error Log Destination
Command
Command
Log
Error Log
paircreate -vr
Local instance
Remote
instance
pairresync
(Issuing the command from an instance on the
primary volume side)
Local instance
Local instance
pairresync
(Issuing the command from an instance on the
secondary volume side)
Local instance
Remote
instance
C:\HORCM\etc>paircreate -g si -d si-3 -vl -c 8
paircreate: [EX_CMDRJE] An order to the control/command device was rejected
Refer to the command log(C:\HORCM\log0\horcc_y1qo6quetvq70ri_log.txt) for details.
It was rejected due to SKEY=0x05, ASC=0x96, ASCQ=0x1C, SSB=0x8400,0x00D0 on
Serial#(87000018)
Sense code (961C)
Sub-code (84)
Detailed code (00D0)
Содержание AMS 2000 Series
Страница 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...