Performing CCI Operations
1–93
Hitachi AMS 2000 Family Command Control Interface (CCI) Reference Guide
Mkconf command tool
The mkconf command executes the following operation and creates a
configuration definition file automatically from the special file via STDIN.
The user must edit the created configuration definition file as needed.
1. The mkconf command executes inqraid –sort –CM –CLI and then
creates a configuration definition file only for HORCM_CMD.
2. The mkconf command starts the HORCM instance using the created
definition file.
3. The mkconf command executes raidscan –find conf by using the
special file via STDIN, and then creates the definition file that contains
HORCM_DEV and HORCM_INST.
4. The mkconf command starts the HORCM instance again to verify the
created definition file.
5. The mkconf command executes raidscan –find verify and displays the
correspondence between the special files via STDIN with the definition
file.
•
•
Table 1-35: Mkconf Command Parameters
Parameter
Value
Command
Name
mkconf
Format
/HORCM/usr/bin/mkconf.sh
[-g[g] <group> [-m <mu#>] [-I
<inst#>] [-s <service>] [-a] ]
\HORCM\etc\ mkconf.exe
[-g[g] <group> [-m <mu#>] [-I <inst#>]
[-s <service>] [-a] [-c <drive>]]
Options
If no argument, this command creates a mode that waits for STDIN
without argument.
-g[g] <group>: This option specifies the group described in the
configuration definition file. If omitted, “VG” is used for the group
name. -gg option is specified to find host group and to display LUN.
-m <MU#>: This option specifies the mirror descriptor MU#.
-I <inst>: This option shows the instance number.
-s <service>: This option specifies the service name (port number)
described in the configuration definition file. If omitted, “52323” is
used for the port number.
-a: This option adds a group to an already created configuration
definition file.
-c <drive>: This option specifies the range of the command device to
be searched. If omitted, “$PhysicalDrive” is used for <drive>.
Note
The configuration definition file and the log file are created in the
current directory as horcm*.conf or log* (* as an instance number).
The user must edit the created configuration definition file as
necessary (such as ip_addresses, and services).
WARNING! If you create the configuration definition file using the mkconf
command tool, remember to change poll(‘0ms) manually. Setting the value
incorrectly may cause a conflict between the CCI and the array, which
causes the internal process of the array to suspend temporary.
Содержание AMS 2000 Series
Страница 6: ...vi Table of Contents Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 226: ...3 70 Maintenance log and tracing functions Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 244: ...4 18 Command options Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...
Страница 261: ...1 Hitachi AMS 2000 Family Command Control Interface CCI Reference Guide ...