background image

A

BOUT

 

THE

 S

YSTEM

S

YSTEM

 R

EAR

 V

IEW

7

Front Control Panel (FCP)

System Rear View

Figure 3.

 

Front Control Panel

Table 4: Front Control Panel Descriptions

N

O

.

I

CON

N

AME

D

ESCRIPTIONS

1

Power button with 
LED

Power on / off
Blue on - S0 system power on; Off - S5 system power off

2

Reset button

Soft reset system function

3

Identification button 
with LED

Toggles ID LED, activate ID LED to identify system
Blue blinking - Identifier on front and rear chassis; Off - Normal.

4

System Status LED

Provides critical and non-critical failure notification
Amber blinking - failed; Off - SEL cleared / good

Table 5: System Rear View

N

O

.

F

EATURE

D

ESCRIPTIONS

1

Power sub-system

Main power supply unit (PSU0). See 

Power Sub-System 

on page

 

9.

2

System I/O ports

See 

System Rear I/O 

on page

 

8

3

Expansion slot

Support OCP 2.0 mezzanine card installation (CPU0)

Reset

1

2

3

4

Reset

1

7

4

5

6

2

 

3

 

Figure 4.

 

System Rear View

8

9

Содержание Advanced Server DS120

Страница 1: ...he system overview and specifications for Hitachi Advanced Server DS120 including hardware component descriptions ports network interface cards and LEDs MK 97HAS010 00 April 2018 Hitachi Advanced Server DS120 Hardware Guide ...

Страница 2: ...aws Notice on Export Controls The technical data and technology inherent in this Document may be subject to U S export control laws including the U S Export Administration Act and its associated regulations and may be subject to export or import regulations in other countries Reader agrees to comply strictly with all such regulations and acknowledges that Reader has the responsibility to obtain li...

Страница 3: ...System 5 System Overview 5 System Front View 6 Front Control Panel FCP 7 System Rear View 7 System Rear I O 8 Power Sub System 9 HDD M 2 Adapter Configuration 10 Full 2 5 HDD Configuration 10 NVMe SSD M 2 Adapter Add On Card Optional 11 LED Status Descriptions 12 Front Control Panel LEDs 12 BMC Management Port LEDs 12 Storage Drive LED 13 ...

Страница 4: ...ons and the names of the folders menus programs and files Enter type face denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES SIMILAR TO NOTES AND WARNINGS CAUTIONS HOWEVER APPEAR IN CAPITAL LETTERS AND CONTAIN VITAL HEALTH AND SAFETY I...

Страница 5: ...viced only by technically qualified persons You must adhere to the guidelines in this guide and the assembly instructions in related chapters to ensure and maintain compliance with existing product certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product a...

Страница 6: ...ces In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power system because they serve as the product s main power disconnect Provided with either two independent DC pow...

Страница 7: ...T BE DISCONNECTED FROM THE POWER SYSTEM IN ORDER TO FULLY SEPARATE THE SYS TEM FROM THE POWER SOURCE CAUTION TO AVOID RISK OF ELECTRIC SHOCK DISCONNECT ALL CABLING FROM THE SYSTEM AND REMOVE THE SYSTEM FROM THE RACK CAUTION TO AVOID PERSONAL INJURY OR PROPERTY DAMAGE THE FOLLOWING SAFETY INSTRUCTIONS APPLY WHENEVER ACCESSING THE INSIDE OF THE PRODUCT Disconnect from the power source by removing th...

Страница 8: ...be such that a haz ardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over cur rent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Re...

Страница 9: ...n non compliance with product regulations in the region s in which the product is sold System power on off To remove power from system you must remove the system from rack Make sure the system is removed from the rack before opening the chassis adding or removing any non hot plug components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power telephone an...

Страница 10: ...mper with the pliers never the wide sides Gripping the wide sides can dam age the contacts inside the jumper causing intermittent problems with the function con trolled by that jumper Take care to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break General Information Before servicing this system it is recommened to read this guide ...

Страница 11: ...ted equipment for use in a server room or computer room using an approved customer rack The enclosure is designed to carry only the weight of the system sled Do not place additional load onto any equipment Heavy object Indicates two people are required to safely handle the system ...

Страница 12: ...About the System This guide provides the system overview and specifications for Hitachi Advanced Server DS120 including hardware component descriptions ports network interface cards and LEDs ...

Страница 13: ...l C624 as 2x or 4x 10GbE integrated network solution with PHY optional The dual port or quad port PHY card is installed to OCP mezzanine slot Specifications Note The system supports 500W and 800W Titanium Platinum redundant PSU 100 240VAC 50 60Hz AC HVDC 1100W redundant DC PSU Acbe I P DC 39 72v 37A max Table 1 1 System Specifications SPECIFICATIONS DESCRIPTION Form factor 1U rack mount Chassis di...

Страница 14: ...NVMe SSD Onboard storage 2 SATADOM optional Video Integrated Aspeed AST2500 with 8MB video memory Network options 1 GbE dual or quad port OCP mezzanine PHY card Optional 1 10GbE dual or quad port OCP mezzanine PHY card Optional Front I O Power ID Reset Buttons Power ID Status LEDs 2 USB 3 0 ports Rear I O 2 USB 3 0 ports 1 VGA port 1 RS232 serial port 1 GbE RJ45 management port 1 ID LED 1 MicroSD ...

Страница 15: ...nt IPMI v2 0 Compliant on board KVM over IP support Operating environment Operating temperature 5 C to 40 C 41 F to 104 F Non operating temperature 40 C to 70 C 40 F to 158 F Operating relative humidity 20 to 85 RH Non operating relative humidity 10 to 95 RH Table 1 1 System Specifications Continued SPECIFICATIONS DESCRIPTION CPU0 CPU1 Slot 3 CPU 1 LP MD2 PCIex16 Slot 1A CPU 0 Slot 4 CPU 0 FHHL PC...

Страница 16: ...UT YOUR SYSTEM PACKAGE CONTENTS 4 1 2 Package Contents 1 DS120 1U system 2 processor heat sinks 1 power supply unit 1 power cord optional Note For exact shipping contents contact your sales representative ...

Страница 17: ...ntrol panel 2 Asset tag Record serial number or other important information 3 2 5 storage drive tray Housing up to twelve 2 5 storage drive 15mm 4 USB port Connect to USB device 5 Thumb screw Secure the system to rack frame 6 Mainboard System mainboard 7 PSU assembly Redundant power supply unit assembly 8 Riser assembly CPU1 Support PCIe add on card installation with riser feature 9 OCP slot CPU0 ...

Страница 18: ... SAS add on card 13 DIMM slots 12 DDR4 DIMM slots per CPU 14 Fan module 8 System fan modules Table 3 Front View NO NAME DESCRIPTIONS 1 Thumb screw Secure the system to rack frame 2 2 5 storage drive tray Housing up to twelve 2 5 storage drive 15mm 3 USB port Connect to USB device 4 Asset tag Record serial number or other important information 5 Front control panel See Front Control Panel LEDs on p...

Страница 19: ... Toggles ID LED activate ID LED to identify system Blue blinking Identifier on front and rear chassis Off Normal 4 System Status LED Provides critical and non critical failure notification Amber blinking failed Off SEL cleared good Table 5 System Rear View NO FEATURE DESCRIPTIONS 1 Power sub system Main power supply unit PSU0 See Power Sub System on page 9 2 System I O ports See System Rear I O on...

Страница 20: ...on slot PCIe expansion slot with FHHL CPU0 Figure 5 System Rear I O Table 6 System Rear I O Descriptions NO ICON NAME DESCRIPTIONS 1 Dedicated NIC Dedicated RJ45 connector 2 VGA connector Maximum display resolution 1920x1200 32bpp 60Hz reduced blanking 3 COM A port DB9 port Serial_A for debug or terminal concentrator 4 USB 3 0 port USB 1 port connect to USB device 5 USB 0 port connect to USB devic...

Страница 21: ...iciency redundant DC PSU DC 39 72V 37A max Table 9 Power Supply Unit LED PSU LED COLOR DESCRIPTION Amber On PSU failure Green On PSU good Green Blinking at 0 5Hz PSU standby Green Blinking at 2Hz PSU cold redundancy standby PSU Figure 6 PSU to Mainboard Module Description A single power supply unit default is supplied in the system A secondary PSU is available for redundancy functionality Table 7 ...

Страница 22: ...el VMD PCIe Root Port BIOS Setup Option Table only for NVMe SSD HDD SLOT ALL FLASH SKU TIERED SKU CPU SOCKET PSTACK VMD PORT CPU SOCKET PSTACK VMD PORT 0 0 0 1A N A 1 1B 2 2 3A 3 3B 4 3C 5 3D 6 1 0 1A 7 1B 8 1C 0 0 1A 9 1D 1B 10 2 3A 1 2 3A 11 3B 3B HDD0 HDD1 HDD2 HDD3 HDD4 HDD5 HDD6 HDD7 HDD8 HDD9 HDD10 HDD11 ALL FLASH SKU HDD0 HDD11 support SATA or NVMe SSD TIERED SKU HDD0 HDD7 support SATA SAS ...

Страница 23: ...ABOUT THE SYSTEM HDD M 2 ADAPTER CONFIGURATION 11 NVMe SSD M 2 Adapter Add On Card Optional Figure 8 M 2 Slot Number M 2 Slot1 M 2 Slot2 ...

Страница 24: ...ED Blue On System S0 power on Off System S5 power off Identification Blue Blinking Unit selected for identification Off No identification request Status LED Amber Blinking Critical Failure critical fan voltage temperature state Non Critical Failure non critical fan voltage temperature state CPU thermal trip DC off Off SEL cleared Last pending warning or error has been de asserted Figure 10 GbE RJ4...

Страница 25: ...nditions Table 15 2 5 Storage Drive LED Status Behavior NAME COLOR CONDITION DESCRIPTIONS Drive Status Fault Blue On Drive is online Blinking Twice per second Identification Once per second Rebuilding Amber On HDD failure Off Slot is empty Drive Active Blue Blinking HDD access is active Table 16 Storage Drive LED Status Behavior NAME COLOR CONDITION DESCRIPTIONS Drive Status Fault Blue Blinking Tw...

Страница 26: ...hiVantara com community HitachiVantara com Regional Contact Information Americas 1 866 374 5822 or info hitachivantara com Europe Middle East and Africa 44 0 1753 618000 or info emea hitachivantara com Asia Pacific 852 3189 7900 or info marketing apac hitachivantara com Hitachi Vantara ...

Отзывы: