LED S
TATUS
D
ESCRIPTIONS
1
2
A
BOUT
THE
S
YSTEM
LED Status Descriptions
Front Control Panel LEDs
For location of the FCP, see
System Front View
on page
6.
Figure 9.
Front Control Panel LEDs
BMC Management Port LEDs
The system mainboard includes one dedicated RJ45 GbE management port. The RJ45 con-
nector has two built-in LEDs. See the following illustration and table for details.
Table 13: Front Control Panel LEDs Behavior
N
AME
C
OLOR
C
ONDITION
LED S
TATUS
D
ESCRIPTIONS
Power LED
Blue
On
System S0 power on
Off
System S5 power off
Identification
Blue
Blinking
Unit selected for identification
Off
No identification request
Status LED
Amber
Blinking
Critical Failure: critical fan, voltage, temperature state.
Non-Critical Failure: non-critical fan, voltage, temperature
state, CPU thermal trip, DC off.
Off
SEL cleared
Last pending warning or error has been de-asserted.
Figure 10. GbE RJ45 Management Port
Table 14: RJ45 LED Descriptions
C
ONDITION
L
INK
A
CTIVITY
Unplugged
Off
Off
1G active link
On amber
Blinking green
100M active link
On green
Blinking green
10M active link
Off
Blinking green
Reset
Power LED
ID LED
Status LED
Link
Activity
PIN 1
Location