P A G E 0 9- 0 1
TROUBLE SHOOTING (NO R A S T ER NO POWER DP-8X Series Chassis.
No
Raster
DP-85 CHASSIS TROUBLESHOOTING
1.) No Raster and No Power (How to check Diagnosis LED's)
(Control PWB)
Is Power
Indicator Red LED
"on"? DM09
(Power PWB)
Check
DIAGNOSIS
Red LED
(Power PWB)
Is Click shound of
relay heard?
S901
(Deflection PWB)
Check Diagnosis
Red LED
(Deflection PWB)
Is Red LED
"Blinking"?
Protection
(Deflection PWB)
1. Trun OFF Power SW.
2. Turn ON again after several
minutes and carefull observe
ALL green LED's
(Deflection PWB)
1. Trun OFF Power SW.
2. Turn ON again after several
minutes and carefull observe
ALL green LED's
(Power PWB)
Is Red LED "OFF"?
Protection
(Deflection PWB)
Did 5 green LED's
turn OFF
same Time?
(Deflection PWB)
Did 5 green LED's
turn OFF
same Time?
No
Yes
Yes
A
No
B
No
Yes
No
C
Yes
R
Didn't
Light at
ALL
G
E
Yes
No
F
No
D
Yes
No means ON but
NOT Blinking.
If Blinking, go to
"B"